高级检索
当前位置: 首页 > 详情页

Anterior Segment OCT in Primary Angle Closure Disease Compared With Normal Subjects With Similar Shallow Anterior Chamber.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]College of Letters & Science, University of California, Berkeley, Berkeley. [2]Department of Ophthalmology, University of California, San Francisco. [3]Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan. [4]Department of Ophthalmology, Center for Preventive Ophthalmology and Biostatistics, University of Pennsylvania, Philadelphia, PA. [5]State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou. [6]Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China. [7]Ophthalmology Section, Surgical Service, San Francisco Veterans Affairs Medical Center, San Francisco, CA.
出处:
ISSN:

摘要:
Compared with normal subjects with similar shallow anterior chamber depth (ACD), patients with primary angle closure disease (PACD) had narrower angle structures measured by swept-source optical coherence tomography (SS-OCT) at 250 μm from scleral spur (very root of iris), especially along oblique and vertical axis.To examine anterior segment structures in normal subjects whose ACD was shallow on slit-lamp examination but did not meet the diagnostic criteria of PACD, and to compare them with PACD patients with similar ACD.Patients were recruited from glaucoma clinic at Zhongshan Ophthalmic Center. A total of 40 eyes from 29 PACD patients and 40 eyes from 34 normal subjects received full ophthalmic examination and CASIA SS-1000 OCT tests. PACD eyes and control eyes were 1:1 matched for ACD at 0 degree of scan. Generalized linear model that accounted for inter-eye correlation was used to compare differences between the 2 groups for intraocular pressure and SS-OCT parameters. P-values were adjusted for multiple comparisons using the Bonferroni method.The PACD and control groups had similar age, but the PACD group had a significantly higher intraocular pressure (18.4 vs. 14.0 mm Hg, P=0.005). Angle parameters, representative of angle area, such as angle recess area and trabecular iris space area measured at 250 μm along axes of 90, 135, 225, and 315 degrees were significantly smaller in PACD group than those of control group (adjusted P<0.05), while most of angle parameters at 500 and 750 μm, volume parameters, and anterior chamber parameters, were similar (adjusted P>0.05).In PACD patients compared with normal subjects with similar anterior chamber shallowing, OCT findings measured at the iris root 250 μm from the scleral spur, especially in the oblique and vertical axes, including angle recess area and trabecular iris space area, may match gonioscopic findings more closely and provide further insight into mechanisms of PACD.Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 3 区 医学
小类 | 4 区 眼科学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
JCR分区:
出版当年[2020]版:
Q3 OPHTHALMOLOGY
最新[2023]版:
Q2 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]College of Letters & Science, University of California, Berkeley, Berkeley.
共同第一作者:
通讯作者:
通讯机构: [2]Department of Ophthalmology, University of California, San Francisco. [7]Ophthalmology Section, Surgical Service, San Francisco Veterans Affairs Medical Center, San Francisco, CA. [*1]Wayne and Gladys Valley Center of Vision, University of California, San Francisco, 490 Illinois Street, San Francisco, CA 94131
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)