高级检索
当前位置: 首页 > 详情页

A Fully Automated Segmentation and Morphometric Parameter Estimation System for Assessing Corneal Endothelial Cell Images.

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Ophthalmology, Peking University Third Hospital, Beijing, China [2]Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing, China [3]Research Center for Brain-inspired Intelligence, Institute of Automation, Chinese Academy of Sciences, Beijing, China
出处:
ISSN:

摘要:
To develop a fully automated segmentation and morphometric parameter estimation system for assessing corneal endothelial cells from in vivo confocal microscopy images.Artificial intelligence (neural network) study.First, a fully automated deep learning system for assessing corneal endothelial cells was developed using the development set (from 99 subjects). Second, 184 images (from 97 subjects) were used to construct the testing set to evaluate the clinical validity and usefulness of the automated segmentation and morphometric system. Third, the automatically calculated endothelial cell density (ECD) values, Topcon's cell density, and manually calculated ECD were compared.After slit lamp examination, 88 healthy subjects, 2 Fuchs endothelial dystrophy patients, and 7 corneal endotheliitis patients were identified among the 97 subjects in the testing set. The automatedly estimated morphometric parameters for the testing set were an average number of 234 cells, an ECD of 2592 cells/mm2, a coefficient of variation in the cell area of 32.14%, and a percentage of hexagonal cells of 54.16%. Pearson's correlation coefficient between the automated ECD and Topcon's cell density and between the manually calculated ECD and Topcon's cell density was 0.932 (P < .01) and 0.818 (P < .01), respectively. The Bland-Altman plot of Topcon's cell density and the automated ECD yielded 95% limits of agreement between 271.94 and -572.46 (concordance correlation coefficient = 0.9).A fully automated method for segmenting corneal endothelial cells and estimating morphometric parameters using in vivo confocal microscopy images is more efficient and accurate for assessing the normal corneal endothelium.Copyright © 2022 Elsevier Inc. All rights reserved.

语种:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 2 区 医学
小类 | 1 区 眼科学
最新[2025]版:
大类 | 1 区 医学
小类 | 1 区 眼科学
第一作者:
第一作者机构: [1]Department of Ophthalmology, Peking University Third Hospital, Beijing, China [2]Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing, China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Ophthalmology, Peking University Third Hospital, Beijing, China [2]Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing, China [*1]No. 49 Garden North Road, Haidian, Beijing, 100191, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23549 今日访问量:0 总访问量:1282 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)