高级检索
当前位置: 首页 > 详情页

CVIS: Automated OCT-scan-based software application for the measurements of choroidal vascularity index and choroidal thickness.

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Ophthalmology, Peking University Third Hospital, Beijing, China. [2]Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Beijing, China. [3]Sino-German Joint Software Institute, Beihang University, Beijing, China. [4]State Key Laboratory of Software Development, Beihang University, Beijing, China.
出处:
ISSN:

摘要:
To develop an automated image recognition software for the objective quantification of choroidal vascularity index (CVI) and choroidal thickness (CT) at different choroidal locations on images obtained from enhanced depth imaging optical coherence tomography (EDI-OCT), and to validate its reliability and investigate the difference and correlation between measurements made by manual and software.A total of 390 EDI-OCT scans, captured from 130 eligible emmetropic or myopic subjects, were categorized into four grades in terms of their accessibility to identify the choroidal-scleral interface (CSI) and were further assessed for CT and CVI at five locations (subfoveal, nasal, temporal, superior and inferior) by the newly developed Choroidal Vascularity Index Software (CVIS) and three ophthalmologists. Choroidal parameters acquired from CVIS were evaluated for its reliability and correlation with ocular factors, in comparison to manual measurements. Distribution of difference and correlation coefficient between CVIS and manual measurements were also analysed.Choroidal Vascularity Index Software (CVIS) demonstrated excellent intra-session reliability for CT (ICC: 0.992) and CVI (ICC: 0.978) measurements, compared to the relatively lower intra- and inter-observer reliability of manual measurements. Choroidal Vascularity Index Software (CVIS) and manual assessments had the highest correlation at nasal choroid (CT: r = 0.829, p < 0.001; CVI: r = 0.665, p < 0.001). Choroidal parameters identified with CVIS showed stronger correlations with axial length than manual measurements.This automated software, CVIS, exhibited excellent reliability compared to manual measurements, which are subject to image quality and clinical experience. With its validated clinical relevance, CVIS holds promise to serve as a flexible and robust tool in future vitreoretinal and chorioretinal studies.© 2022 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

语种:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 3 区 医学
小类 | 2 区 眼科学
最新[2023]版:
大类 | 3 区 医学
小类 | 2 区 眼科学
第一作者:
第一作者机构: [1]Department of Ophthalmology, Peking University Third Hospital, Beijing, China. [2]Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Beijing, China.
共同第一作者:
通讯作者:
通讯机构: [1]Department of Ophthalmology, Peking University Third Hospital, Beijing, China. [2]Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Beijing, China. [3]Sino-German Joint Software Institute, Beihang University, Beijing, China. [4]State Key Laboratory of Software Development, Beihang University, Beijing, China. [*1]49 North Garden Road Haidian District, 100191 Beijing, China [*2]37 Xueyuan Road Haidian District, 100191 Beijing, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21205 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)