高级检索
当前位置: 首页 > 详情页

Vault changes and pupillary responses to light in myopic and toric implantable collamer lens

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Ophthalmology,Beijing Tongren Eye Center,Beijing TongrenHospital,Capital Medical University,No.1 Dongjiaomin Lane,DongchengDistrict,BeiJing 100,000,China [2]Beijing Institute of Ophthalmology,BeijingTongren Eye Center,Beijing Tongren Hospital,Capital Medical University,Beijing,China [3]Beijing Advanced Innovation Center for Big Data‑Based PrecisionMedicine, Beihang University & Capital Medical University, Beijing TongrenHospital, Beijing, China
出处:
ISSN:

关键词: Implantable collamer lens High myopia Vault Pupillary response

摘要:
Background Achieving an appropriate vault is the main concern after the implantation of Implantable Collamer Lens (ICLs) for surgical correction of high myopia. The vault will vary with time and optical parameters, such as accommodation and pupil size. This research is to evaluate the vault change in Myopic and Toric ICLs under different lighting conditions; and to analyze the relationship between vault changes and pupillary responses to light. Methods We enrolled and analyzed 68 eyes from 68 patients who were implanted with Myopic EVO ICLs; we also included 60 eyes from 60 patients who were implanted with Toric EVO ICLs. The anterior chamber depth, pupil size and the post-operative vault were evaluated, 1 week after the operation, using a Visante Optical Coherence Tomography (OCT) under different lighting conditions. For each eye that was assessed, we calculated the vault change, which is defined as the difference between vault under mesopic condition and photopic condition; and the rate of vault change, which is defined as the vault change divided by mesopic vault. Results No significant difference was noted with the anterior chamber depth between mesopic and photopic conditions in either group. A significant decrease in vault and pupil size was detected under photopic condition in both groups. We found no difference in vault change between Myopic and Toric EVO ICLs under different lighting conditions. Moreover, the rate of vault change had a significant decrease with increased mesopic vault (baseline value). Conclusions Too low a mesopic vault has a big rate of vault change, which may cause the contact of ICL with crystalline lens in photopic state; Too high a mesopic vault would constrict the posterior movement of pupil. The findings of the study suggest that, for patients with high or low vault, we should be more careful and must perform checks in different lighting conditions.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2023]版:
大类 | 4 区 医学
小类 | 3 区 眼科学
JCR分区:
出版当年[2019]版:
Q3 OPHTHALMOLOGY
最新[2023]版:
Q3 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Department of Ophthalmology,Beijing Tongren Eye Center,Beijing TongrenHospital,Capital Medical University,No.1 Dongjiaomin Lane,DongchengDistrict,BeiJing 100,000,China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21193 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)