高级检索
当前位置: 首页 > 详情页

Detection of shallow anterior chamber depth from two-dimensional anterior segment photographs using deep learning.

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Ophthalmology, Shanghai Aier Eye Hospital, No. 1286, Hongqiao Road, Changning District, Shanghai 200050, China. [2]Aier School of Ophthalmology, Central South University Changsha, Changsha, Hunan Province, China. [3]Joint Shantou International Eye Center of Shantou University and the Chinese University of Hong Kong, Shantou University Medical College, Shantou, Guangdong, China. [4]Ningbo Institute of Industrial Technology, Chinese Academy of Sciences, Beijing, China. [5]Department of Ophthalmology, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, No.1665, Kongjiang Road, Yangpu District, Shanghai 200092, China. [6]Department of Ophthalmology, Shanghai Children’s Hospital, Shanghai Jiao Tong University, Shanghai, China. [7]Department of Ophthalmology, Shibei Hospital, Shanghai, China. [8]Department of Ophthalmology, Zhabei CenterHospital, Shanghai, China. [9]Department of Ophthalmology, Shanghai Aier Qingliang Eye Hospital, Changning, China. [10]Aier Eye Hospital, Jinan University, No.601, Huangpu Road West, Guangzhou, P.R. China.
出处:

摘要:
The purpose of this study was to implement and evaluate a deep learning (DL) approach for automatically detecting shallow anterior chamber depth (ACD) from two-dimensional (2D) overview anterior segment photographs.We trained a DL model using a dataset of anterior segment photographs collected from Shanghai Aier Eye Hospital from June 2018 to December 2019. A Pentacam HR system was used to capture a 2D overview eye image and measure the ACD. Shallow ACD was defined as ACD less than 2.4 mm. The DL model was evaluated by a five-fold cross-validation test in a hold-out testing dataset. We also evaluated the DL model by testing it against two glaucoma specialists. The performance of the DL model was calculated by metrics, including accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve (AUC).A total of 3753 photographs (1720 shallow AC and 2033 deep AC images) were assigned to the training dataset, and 1302 photographs (509 shallow AC and 793 deep AC images) were held out for two internal testing datasets. In detecting shallow ACD in the internal hold-out testing dataset, the DL model achieved an AUC of 0.86 (95% CI, 0.83-0.90) with 80% sensitivity and 79% specificity. In the same testing dataset, the DL model also achieved better performance than the two glaucoma specialists (accuracy of 80% vs. accuracy of 74 and 69%).We proposed a high-performing DL model to automatically detect shallow ACD from overview anterior segment photographs. Our DL model has potential applications in detecting and monitoring shallow ACD in the real world.http://clinicaltrials.gov , NCT04340635 , retrospectively registered on 29 March 2020.© 2021. The Author(s).

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
第一作者:
第一作者机构: [1]Department of Ophthalmology, Shanghai Aier Eye Hospital, No. 1286, Hongqiao Road, Changning District, Shanghai 200050, China. [2]Aier School of Ophthalmology, Central South University Changsha, Changsha, Hunan Province, China.
通讯作者:
通讯机构: [1]Department of Ophthalmology, Shanghai Aier Eye Hospital, No. 1286, Hongqiao Road, Changning District, Shanghai 200050, China. [2]Aier School of Ophthalmology, Central South University Changsha, Changsha, Hunan Province, China. [9]Department of Ophthalmology, Shanghai Aier Qingliang Eye Hospital, Changning, China. [10]Aier Eye Hospital, Jinan University, No.601, Huangpu Road West, Guangzhou, P.R. China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23405 今日访问量:0 总访问量:1276 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)