MERCI: a machine learning approach to identifying hydroxychloroquine retinopathy using mfERG.

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Computer Science, University of Toronto, Toronto, Canada. [2]Department of Mathematics and Statistics, York University, Toronto, Canada. [3]Research Center for Mathematics, Advanced Institute of Natural Sciences, Beijing Normal University, Zhuhai, China. [4]BNU-HKBU United International College, Zhuhai, China. [5]Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Canada. [6]Kensington Vision and Research Centre, Toronto, Canada.
出处:
ISSN:

关键词: mfERG Ring ratios Hydroxychloroquine Reference ranges SVM Machine learning

摘要:
Hydroxychloroquine (HCQ) is an anti-inflammatory drug in widespread use for the treatment of systemic auto-immune diseases. Vision loss caused by retinal toxicity is a significant risk associated with long term HCQ therapy. Identifying patients at risk of developing retinal toxicity can help prevent vision loss and improve the quality of life for patients. This paper presents updated reference thresholds and examines the diagnostic accuracy of a machine learning approach for identifying retinal toxicity using the multifocal Electroretinogram (mfERG).A retrospective study of patients referred for mfERG testing to detect HCQ retinopathy. A consecutive series of all patients referred to Kensington Vision and Research Centre between August 2017 and July 2020 were considered eligible. Eyes suspect for other ocular pathology including widespread retinal disease and advanced macular pathology unrelated to HCQ or with poor quality mfERG recordings were excluded. All patients received mfERG testing and Ocular Coherence Tomography (OCT) imaging. Presence of HCQ retinopathy was based on ring ratio analysis using clinical reference thresholds established at KVRC coupled with structural features observed on OCT, the clinical reference standard. A Support Vector Machine (SVM) using selected features of the mfERG was trained. Accuracy, sensitivity and specificity are reported.1463 eyes of 748 patients were included in the study. SVM model performance was assessed on 293 eyes from 265 patients. 55 eyes from 54 patients were identified as demonstrating HCQ retinopathy based on the clinical reference standard, 50 eyes from 49 patients were identified by the SVM. Our SVM achieves an accuracy of 85.3% with a sensitivity of 90.9% and specificity of 84.0%.Machine learning approaches can be applied to mfERG analysis to identify patients at risk of retinopathy caused by HCQ therapy.© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
第一作者:
第一作者机构: [1]Department of Computer Science, University of Toronto, Toronto, Canada.
通讯作者:
通讯机构: [5]Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Canada. [6]Kensington Vision and Research Centre, Toronto, Canada.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:25471 今日访问量:0 总访问量:1498 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)