高级检索
当前位置: 首页 > 详情页

Elastography Assisted BI-RADS in the Preoperative Breast Magnetic Resonance Imaging 4a Lesions in China

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Shanghai Jiao Tong Univ, Sch Med, Tongren Hosp, Dept Ultrasound Med, Shanghai, Peoples R China [2]Fudan Univ, Dept Ultrasound Med, Minhang Hosp, Shanghai, Peoples R China
出处:
ISSN:

关键词: breast biopsy elastography magnetic resonance imaging ultrasound

摘要:
Objectives A considerable number of benign lesions, especially category 4a lesions on Breast Imaging Reporting and Data System Magnetic Resonance Imaging (BI-RADS-MRI), were biopsied according to BI-RADS-MRI, which was a diagnostic imaging challenge. This study aimed to evaluate the diagnostic performance of ultrasound elastography (UE) assisted Breast Imaging Reporting and Data System (BI-RADS) for BI-RADS-MRI category 4a lesions. Methods Between January 2017 and December 2019, 228 breast lesions categorized as BI-RADS-MRI 4a were included. Conventional ultrasound (US) and UE were performed to evaluate each lesion. Pathology results were used as the gold standard. The diagnostic performances of different UE methods and our re-assessment proposal were evaluated. Results When BI-RADS-MRI category 4a, BI-RADS-US category 3-4a, the stiffness of soft or intermediate in elasticity assessment according to the fifth edition of the BI-RADS atlas, strain ratio < 1.335, age <= 52 years, and the maximum diameter of lesion <= 20 mm were simultaneously met, an ultrasound-guided empty needle biopsy was not recommended, but short-term ultrasound follow-up for 3-6 months was recommended, and biopsy was performed after changes in evaluation. In this way, 95 of 228 BI-RADS-MRI category 4a lesions avoided biopsies, and the number of patients with biopsies decreased by 41.7%. Conclusions UE offers benefits in the characterization of BI-RADS-MRI category 4a lesions. Ultrasound and elastography can help optimize therapy recommendations for BI-RADS-MRI category 4a lesions by our re-assessment proposal.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 3 区 声学 4 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 3 区 声学 4 区 核医学
JCR分区:
出版当年[2021]版:
Q2 ACOUSTICS Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q2 ACOUSTICS

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Shanghai Jiao Tong Univ, Sch Med, Tongren Hosp, Dept Ultrasound Med, Shanghai, Peoples R China
通讯作者:
通讯机构: [1]Shanghai Jiao Tong Univ, Sch Med, Tongren Hosp, Dept Ultrasound Med, Shanghai, Peoples R China [*1]1111 Xianxia Rd, Shanghai 200336, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21166 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)