资源类型:
期刊
WOS体系:
Article
Pubmed体系:
Journal Article
收录情况:
◇ SCIE
◇ 预警期刊
文章类型:
论著
机构:
[1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
首都医科大学附属北京同仁医院
首都医科大学附属同仁医院
ISSN:
2296-858X
关键词:
total keratometry
IOLMaster 700
corneal refractive surgery
cataract
IOL calculation
摘要:
More recently, the swept-source OCT biometer-IOLMaster 700 has provided direct total corneal power measurement, named total keratometry. This study aims to evaluate whether standard keratometry (SK) and total keratometry (TK) with IOLMaster 700 can accurately reflect the corneal power changes induced by myopic corneal refractive surgery.In this study, the biometric data measured with the swept-source OCT biometer-IOLMaster 700 before and 3 months after the myopic corneal refractive surgery were recorded. The changes of biological parameters, including SK, posterior keratometry (PK), and TK, and the difference between SK and TK were compared. In addition, the changes of SK and TK induced by the surgery were compared with the changes of spherical equivalent at the corneal plane (ΔSEco).A total of 74 eyes (74 patients) were included. The changes of SK, PK, TK, axial length, anterior chamber depth, and lens thickness after refractive surgery were all statistically significant (all p < 0.01), while the change of white-to-white was not (p = 0.075). The difference between SK and TK was -0.03 ± 0.10D before the corneal refractive surgery and increased to -0.78 ± 0.26D after surgery. The changes of SK and the changes of TK induced by the surgery had a good correlation with the changes of SEco (r = 0.97). ΔSK was significantly smaller than ΔSEco, with a difference of -0.65 ± 0.54D (p < 0.01). However, the difference between ΔTK and ΔSEco (0.10 ± 0.50D) was not statistically significant (p = 0.08).Using SK to reflect the changes induced by the myopic corneal refractive surgery may lead to underestimation, while TK could generate a more accurate result. The new parameter, TK, provided by the IOLMaster 700, appeared to provide an accurate, objective measure of corneal power that closely tracked the refractive change in corneal refractive surgery.Copyright © 2022 Wang, Song, Yang, Li, Chen, Zhao, Liu and Zhai.
基金:
Hospital Founding of Beijing
Tongren Hospital (Grant No. 2021-YJJ-PY-002).
被引次数:
1
WOS:
WOS:000885739500001
PubmedID:
35903314
中科院(CAS)分区:
出版当年[2021]版:
大类
|
3 区
医学
小类
|
2 区
医学:内科
最新[2023]版:
大类
|
3 区
医学
小类
|
3 区
医学:内科
JCR分区:
出版当年[2020]版:
Q1
MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1
MEDICINE, GENERAL & INTERNAL
影响因子:
3.1
最新[2023版]
3.4
最新五年平均
5.093
出版当年[2020版]
5.185
出版当年五年平均
3.9
出版前一年[2019版]
5.058
出版后一年[2021版]
第一作者:
Wang Ziyang
第一作者机构:
[1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
通讯作者:
Yang Wenli
推荐引用方式(GB/T 7714):
Wang Ziyang,Song Yanzheng,Yang Wenli,et al.Comparing Standard Keratometry and Total Keratometry Before and After Myopic Corneal Refractive Surgery With a Swept-Source OCT Biometer[J].FRONTIERS IN MEDICINE.2022,9:928027.doi:10.3389/fmed.2022.928027.
APA:
Wang Ziyang,Song Yanzheng,Yang Wenli,Li Dongjun,Chen Wei...&Zhai Changbin.(2022).Comparing Standard Keratometry and Total Keratometry Before and After Myopic Corneal Refractive Surgery With a Swept-Source OCT Biometer.FRONTIERS IN MEDICINE,9,
MLA:
Wang Ziyang,et al."Comparing Standard Keratometry and Total Keratometry Before and After Myopic Corneal Refractive Surgery With a Swept-Source OCT Biometer".FRONTIERS IN MEDICINE 9.(2022):928027