高级检索
当前位置: 首页 > 详情页

Finite element analysis of conductive hearing loss caused by fixation and detachment of ligament and tendon in the middle ear

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Mechanics and Tianjin Key Laboratory of Nonlinear Dynamics and Control, Tianjin University, Tianjin 300350, China [2]Department of Otolaryngology, Head and Neck Surgery, Tianjin Children’s Hospital, Tianjin University, Tianjin 300400, China [3]School of Aerospace Engineering, Tsinghua University, Beijing 100084, China [4]Department of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Key Laboratory of Otolaryngology Head and Neck Surgery, Ministry of Education, Beijing 100730, China [5]Beijing Engineering Research Center of Audiological Technology, Beijing 100730, China
出处:
ISSN:

关键词: Middle ear Motion stability Hearing loss Finite element model Lumped parametric model

摘要:
The fixation of ligament and tendon of the middle ear often occurs after chronic otitis media surgery. However, there are relatively few studies on the effect of ligament and tendon on sound transmission in the human middle ear. Here, the finite element model and lumped parameter model are used to study the effect of ligament and tendon fixation and detachment on sound transmission in human ear.In this paper, the finite element model including the external auditory canal, middle ear and simplified inner ear is used to calculate and compare the middle ear frequency response of the normal and tympanosclerosis under pure tone stimulation. In addition, the lumped parametric model is taken into account to illustrate the effect of ligament and tendon stiffness on the human ear transmission system.The results indicate that the motion of the tympanic membrane and stapes is reduced by ligament and tendon fixation. Although ligament and tendon detachment have a limited effect in the piston-motion direction, the stability of motion in the plane perpendicular to the piston-motion direction is significantly reduced. Most significantly, the ligament and tendon fixation cause a hearing effect of about 18 dB, which is greater in the plane perpendicular to the piston-motion direction after ligament and tendon detachment than in the piston-motion direction.In this study, the calculation accuracy of the lumped parameter and the finite element model is studied, and the effect of ligament and tendon on hearing loss is further explored through the finite element model with high calculation accuracy, which is helpful to understand the role of ligament and tendon in the sound transmission mechanism of the human middle ear. The study of ligament and tendon on conductive hearing loss provides a reference for clinical treatment of tympanosclerosis.Copyright © 2023. Published by Elsevier B.V.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 2 区 工程技术
小类 | 2 区 计算机:跨学科应用 2 区 工程:生物医学 2 区 医学:信息 2 区 计算机:理论方法
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 计算机:跨学科应用 2 区 计算机:理论方法 2 区 工程:生物医学 2 区 医学:信息
JCR分区:
出版当年[2021]版:
Q1 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS Q1 COMPUTER SCIENCE, THEORY & METHODS Q1 ENGINEERING, BIOMEDICAL Q1 MEDICAL INFORMATICS
最新[2023]版:
Q1 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS Q1 COMPUTER SCIENCE, THEORY & METHODS Q1 ENGINEERING, BIOMEDICAL Q1 MEDICAL INFORMATICS

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Department of Mechanics and Tianjin Key Laboratory of Nonlinear Dynamics and Control, Tianjin University, Tianjin 300350, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21166 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)