高级检索
当前位置: 首页 > 详情页

Staphylococcus aureus lysate induces an IgE response via memory B cells in nasal polyps

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China [2]Department of Otolaryngology-Head and Neck Surgery, Eye & ENT Hospital, Fudan University, Shanghai 200031, China. [3]Beijing Laboratory of Allergic Diseases, Beijing Municipal Education Commission and Beijing Key Laboratory of Nasal Diseases, Beijing Institute of Otolaryngology, Beijing 100005, China [4]Department of Immunology, School of Basic Medical Sciences, Capital Medical University, Beijing 100069, China [5]Department of Allergy, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China [6]Research Unit of Diagnosis and Treatment of Chronic Nasal Diseases, Chinese Academy of Medical Sciences, Beijing
出处:
ISSN:

关键词: Chronic rhinosinusitis with nasal polyps Staphylococcus aureus IgE Memory response Recurrence

摘要:
Locally increased IgE levels plays a pathological role in chronic rhinosinusitis with nasal polyps (CRSwNP).This study aimed to investigate whether S. aureus could induce aberrant IgE synthesis in CRSwNP and the potential mechanisms involved.Total IgE, IL-4, IL-5, and IL-13 concentrations in the supernatants of the cultures stimulated with S. aureus lysate were assessed by ELISA. S. aureus-induced cellular responses were investigated by single-cell RNA-sequencing (scRNA-seq). Flow cytometry and RT-PCR were employed to analyze B-cell subsets and stimulated cell ε-germline transcript (ε-GLT) expression, respectively. IgE+ B cell and the germinal center (GC) localization were assessed by immunohistochemistry and immunofluorescence.S. aureus lysate induced IgE production in the supernatants of nasal polyp (NP) tissues but not in those of healthy nasal mucosa. Moreover, IgE levels increased from days 2 to 4 post-stimulation, paralleling the enhanced ε-GLT, IL-5 and IL-13 expression. ScRNA-seq revealed that there were increased IL-5 and IL-13 in group 2 innate lymphoid cells (ILC2s) and identified a clonal overlap between unstimulated memory B cells and S. aureus-stimulated plasma cells. The enriched IgE within NPs was mainly produced by IgE-negative memory B cells. Cellular evidence indicated that the IgE memory response to S. aureus might also exist in the peripheral blood of CRSwNP patients. The S. aureus-induced IgE memory response was associated with elevated IgE levels in NPs, asthma, and postoperative CRSwNP recurrence.S. aureus induced an IgE response via IgE-negative memory B cells in CRSwNP patients, possibly contributing to CRSwNP development.Copyright © 2023. Published by Elsevier Inc.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 1 区 医学
小类 | 1 区 过敏 1 区 免疫学
最新[2023]版:
大类 | 1 区 医学
小类 | 1 区 过敏 1 区 免疫学
JCR分区:
出版当年[2022]版:
Q1 ALLERGY Q1 IMMUNOLOGY
最新[2023]版:
Q1 ALLERGY Q1 IMMUNOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Department of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China [2]Department of Otolaryngology-Head and Neck Surgery, Eye & ENT Hospital, Fudan University, Shanghai 200031, China.
共同第一作者:
通讯作者:
通讯机构: [1]Department of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China [3]Beijing Laboratory of Allergic Diseases, Beijing Municipal Education Commission and Beijing Key Laboratory of Nasal Diseases, Beijing Institute of Otolaryngology, Beijing 100005, China [4]Department of Immunology, School of Basic Medical Sciences, Capital Medical University, Beijing 100069, China [5]Department of Allergy, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China [6]Research Unit of Diagnosis and Treatment of Chronic Nasal Diseases, Chinese Academy of Medical Sciences, Beijing
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21193 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)