高级检索
当前位置: 首页 > 详情页

Improved accuracy of spectral-domain optical coherence tomography and optical coherence tomography angiography for monitoring myopic macular neovascularisation activity

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Peoples R China [2]Hong Kong Baptist Hosp, Hong Kong, Peoples R China [3]Prince Wales Hosp, Dept Ophthalmol & Visual Sci, Hong Kong, Peoples R China [4]Hong Kong Eye Hosp, Hong Kong, Peoples R China [5]OasisEye Specialists, Seremban, Malaysia [6]Beijing Tongren Eye Ctr, Beijing, Peoples R China [7]2010 Retina & Macula Ctr, Hong Kong, Peoples R China
出处:
ISSN:

关键词: Macula Neovascularisation Imaging Diagnostic tests/Investigation Retina

摘要:
Background/aims To evaluate the diagnostic accuracy of spectral-domain optical coherence tomography (SD OCT) combined with OCT angiography (OCTA) for myopic myopic macular neovascularisation (MNV) activity. Methods Both eyes of patients with myopic MNV diagnosed with fluorescein angiography (FA), SD OCT and OCTA were assessed by unmasked investigators. The images were deidentified and randomised before graded by masked investigators, who determined the presence of active myopic MNV by using SD OCT together with OCTA without FA and by FA alone, respectively. The findings of masked investigators were compared with unmasked investigators. Results 213 eyes of 110 patients comprising 499 imaging episodes were eligible for grading. For diagnosing new-onset myopic MNV without FA, combined use of SD OCT and OCTA had a sensitivity of 0.94, specificity of 0.84 and area under the curve (AUC) of 0.92. FA had a sensitivity of 0.52 (p<0.01), specificity of 0.80 (p=0.38) and AUC of 0.66 (p<0.01). For recurrent myopic MNV, the combination of SD OCT and OCTA had a sensitivity of 0.98, specificity of 0.78 and AUC of 0.88. FA had a sensitivity of 0.50 (p=0.04), specificity of 0.76 (p=0.85) and AUC of 0.63 (p=0.01). Myopic traction maculopathy was more frequently associated with recurrent myopic MNV (p<0.01). Conclusion SD OCT with dense volumetric scan was highly sensitive for diagnosing myopic MNV. The addition of OCTA improved the diagnostic specificity without FA. Monitoring of the longitudinal changes on SD OCT and judicious use of FA is a reliable surveillance strategy for myopic MNV.

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
JCR分区:
出版当年[2022]版:
Q1 OPHTHALMOLOGY
最新[2023]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Peoples R China [2]Hong Kong Baptist Hosp, Hong Kong, Peoples R China
通讯作者:
通讯机构: [1]Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Peoples R China [2]Hong Kong Baptist Hosp, Hong Kong, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21166 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)