Improvements in Hemodynamics and Right Heart Remodeling Following Balloon Pulmonary Angioplasty Treatment in Patients With Chronic Thromboembolic Pulmonary Hypertension: A Retrospective Study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ ESCI

机构: [1]School of Medicine Tongji University Shanghai China. [2]Department of Emergency, Shanghai Tongren Hospital Shanghai Jiaotong University School of Medicine Shanghai China. [3]Department of Pulmonary Circulation Shanghai Pulmonary Hospital, Tongji University School of Medicine Shanghai China. [4]Dermatology Hospital Southern Medical University Guangzhou China.
出处:

关键词: balloon pulmonary angioplasty chronic thromboembolic pulmonary hypertension echocardiography right cardiac catheterization

摘要:
This study aimed to evaluate the hemodynamic alterations and right heart remodeling dynamics in patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH) undergoing treatment with balloon pulmonary angioplasty (BPA).This retrospective cohort study involved a cohort of 31 patients with a confirmed diagnosis of CTEPH. Comprehensive clinical evaluations were systematically performed before BPA, and at 3 and 6 months following the procedure.Significant clinical progress was evidenced by the uplift in the percentage of patients achieving WHO-FC II, escalating from 19.35% at baseline to 51.61% at 6 months after BPA (p = 0.003). NT-proBNP levels significantly dropped from a median of 614.6 to 69.9 pg/mL (p < 0.001). Hemodynamic assessments showed significant decreases in mean PAP from 45.53 ± 11.19 to 22.56 ± 5.81 mmHg (p < 0.001) and PVR from 8.33 to 2.86 WU (p < 0.001). Echocardiographic analysis revealed substantial reductions in the right atrial area (RAA, from 20.29 ± 7.55 to 16.79 ± 4.82 cm2, p < 0.001) and right ventricular internal diameter (RVID, from 4.13 ± 0.79 to 3.68 ± 0.59 cm, p = 0.001) at the 3-month interval post-BPA. These improvements were sustained or even enhanced by the 6-month mark, with RAA and RVID further diminishing (to 14.46 ± 3.78 cm2 and 3.29 ± 0.54 cm, respectively; both p < 0.01). The TAPSE/PASP ratios showed progressive improvement from baseline (0.32 ± 0.13) to 3 months (0.42 ± 0.13) and continued to improve at 6 months following BPA (0.50 ± 0.11, p = 0.04 compared to 3 months post-BPA).BPA has significantly ameliorated clinical conditions, hemodynamic profiles, and initiated a continued reversal in right heart remodeling in patients with CTEPH.© 2024 The Authors. Health Science Reports published by Wiley Periodicals LLC.

基金:
语种:
WOS:
PubmedID:
JCR分区:
出版当年[2022]版:
最新[2023]版:
Q2 MEDICINE, GENERAL & INTERNAL Q2 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH Q3 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]School of Medicine Tongji University Shanghai China. [2]Department of Emergency, Shanghai Tongren Hospital Shanghai Jiaotong University School of Medicine Shanghai China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)