Kirigami Design Smart Contact Lens for Highly Sensitive Eyelid Pressure Measurement

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China. [2]Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing 100871, China. [3]National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University, Wenzhou 325000, Zhejiang, China. [4]State Key Laboratory of Nuclear Physics and Technology, School of Physics, Peking University, Beijing 100871, China. [5]Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China.
出处:

关键词: eyelid pressure monitoring iontronic capacitive sensor sensing array kirigami smart contact lens

摘要:
Eyelid pressure is a crucial biomechanical parameter for ocular health and refractive status, yet measuring it poses challenges related to flexibility, sensitivity, and regional specificity. This study introduces a novel smart contact lens that incorporates kirigami designs and an iontronic capacitive sensing array to enhance flexibility and conformability. The unique structural composition of this device allows for precise and simultaneous monitoring of eyelid pressure in multiple regions with a high sensitivity and seamlessly fit across corneal curvatures. The efficacy of the sensor has been thoroughly confirmed through comprehensive evaluations in rabbits and porcine eyes, demonstrating improved conformity and sensitivity compared to conventional single-point sensors. Assessments have been conducted in various conditions, including under anesthesia and in awake states, as well as the deliberate alteration of intraocular pressure fluctuations, all affirming the exceptional accuracy in detecting eyelid pressure. We envision that the smart contact lens has the potential to revolutionize diagnosis and management of eyelid-related ocular diseases.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 1 区 化学
小类 | 1 区 分析化学 2 区 化学:综合 2 区 纳米科技
最新[2023]版:
大类 | 1 区 化学
小类 | 1 区 分析化学 2 区 化学:综合 2 区 纳米科技
JCR分区:
出版当年[2022]版:
Q1 CHEMISTRY, ANALYTICAL Q1 CHEMISTRY, MULTIDISCIPLINARY Q2 NANOSCIENCE & NANOTECHNOLOGY
最新[2023]版:
Q1 CHEMISTRY, MULTIDISCIPLINARY Q1 NANOSCIENCE & NANOTECHNOLOGY Q1 CHEMISTRY, ANALYTICAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21205 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)