Cerebrospinal fluid flow dynamics and volume changes are related with sigmoid sinus wall dehiscence-pulsatile tinnitus with idiopathic intracranial hypertension

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China [2]Department of Radiology, Chongqing Iron and Steel General Hospital, Chongqing 400080, China [3]Department of Otolaryngology Head and Neck surgery, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China [4]Department of Clinical and Technical Support, Philips (China) Investment Co., Ltd., Beijing Branch, Beijing 100600, China
出处:
ISSN:

关键词: Pulsatile tinnitus Sigmoid sinus wall dehiscence Intracranial hypertension Cerebrospinal fluid Obesity

摘要:
To evaluate cerebrospinal fluid (CSF) flow dynamics and volume changes of pulsatile tinnitus (PT) patients induced by sigmoid sinus wall dehiscence (SSWD) with intracranial hypertension.Thirty-five SSWD-PT patients coexisted with intracranial hypertension and 35, age-, gender-, and handedness-matched healthy volunteers were prospectively enrolled and performed MRI. Clinical data were collected. CSF flow dynamics were evaluated by phase-contrast magnetic resonance imaging (PC-MRI) and CSF volume was measured using ITK-SNAP software.Compared with controls, the body mass index (BMI) of PT patients increased significantly (P = 0.046). Among CSF flow dynamics, PT patients presented significantly decreased mean flux (MF) (P = 0.017), mean velocity (MV) (P = 0.038), peak velocity (PV) (P = 0.023), and significantly increased regurgitant fraction (RF) (P = 0.010) than controls. There were no significant differences in other CSF flow dynamics parameters between the groups. CSF volume of PT patients was significantly increased than controls (P = 0.024). RF and CSF volume had potential diagnostic value. The AUC, sensitivity, specificity and accuracy of RF and CSF volume were 0.678, 68.6 %, 60.0 %, 61.4 % and 0.656, 68.6 %, 57.1 %, 55.7 %, respectively. The combined diagnostic efficacy of RF and CSF volume was highest, and the AUC, sensitivity, specificity and accuracy were 0.733, 74.3 %, 62.9 %, 67.1 % respectively.SSWD-PT patients present CSF flow dynamics and volume changes, which may be related to the occurrence of PT. In addition to structural abnormalities, the combination of RF and CSF volume can be innovative as a complementary index to identify SSWD as the accurate etiology of PT.Copyright © 2024. Published by Elsevier Inc.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版]

第一作者:
第一作者机构: [1]Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23624 今日访问量:3 总访问量:1285 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)