高级检索
当前位置: 首页 > 详情页

Effects of low molecular weight heparin on clot rate and activated clotting time: an in vitro study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ CSCD-C ◇ 中华系列

机构: [1]Capital Med Univ, Beijing Tongren Hosp, Ctr Cardiovasc, Beijing 100730, Peoples R China
出处:
ISSN:

关键词: clot rate activated clotting time low molecular weight heparin

摘要:
Background Due to lack of point-of-care testing, the use of low-molecular-weight heparin (LMWH) therapy in some special patients is restricted. This study was designed to explore the effects of LMWH on clot rate (CR) and activated clotting time (ACT), and to search for an appropriate method for bedside monitoring of anticoagulant activity of LMWH. Methods Thirty-two healthy volunteers were selected from the staff of Beijing Tongren Hospital. CR and ACT were measured with different reagents (glass beads, diatomite, kaolin and magnetic bar) on blood samples spiked with increasing concentrations of LMWH (dalteparin, 0.2-1.8 IU/ml). Correlations between concentrations of LMWH and values of CR and ACT were analysed based on the data obtained and regression analysis was performed to establish a regression equation. Results With the increase in doses of dalteparin, CR values reduced gradually. The values of CR of four reagents (glass beads, diatomite, kaolin and magnetic bar) were 20.4-4.5 IU/min, 27.4-6.9 IU/min, 27.5-7.9 IU/min and 7.8-0.1 IU/min respectively and an linear relationship was observed between the CR values and dalteparin concentrations (P<0.05). The values of ACT were 173-615 seconds, 130-270 seconds, 123-226 seconds, 337-1411 seconds respectively, which showed a linear regression between the ACT values and dalteparin concentrations (P<0.01). Differences in slope of the regression curves of ACT were observed with all the reagents tested (glass beads 248.2 s/IU, diatomite 74.8 s/IU, kaolin 58.2 s/IU and magnetic bar 1112.2 s/IU, P<0.01). While the minimum concentration of dalteparin was 0.2 IU/ml, 0.4 IU/ml, 1.4 IU/ml and 0.2 IU/ml separately, the ACT values of the four coagulants (glass beads, diatomite, kaolin and magnetic bar) were beyond the normal limit and showed a noticeable increase respectively (P<0.01). Conclusions This study showed that there was an excellent linear relationship between the CR and ACT values and dalteparin concentrations for all the four reagents (glass beads, diatomite, kaolin and magnetic bar) in vitro. The sensitivity of different coagulation reagents to LMWH different. Choosing a suitable reagent, both CR and ACT were possible to be used as a convenient bedside test for LMWH.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
JCR分区:
出版当年[2011]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tongren Hosp, Ctr Cardiovasc, Beijing 100730, Peoples R China [*1]Cardiovascular Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tongren Hosp, Ctr Cardiovasc, Beijing 100730, Peoples R China [*1]Cardiovascular Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21166 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)