高级检索
当前位置: 首页 > 详情页

Evaluating the scope of intramedullary invasion of malignant bone tumor by DCE-MRI quantitative parameters in an animal study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Wuhan Univ, Tongren Hosp, Wuhan Hosp 3, Dept Radiol, Wuhan 430000, Hubei, Peoples R China [2]Qingdao Univ, Affiliated Hosp, Dept Radiol, Qingdao 266003, Peoples R China
出处:
ISSN:

关键词: VX2 tumor Dynamic contrast enhancement magnetic resonance imaging (DCE-MRI) Intramedullary invasion Micro-infiltration

摘要:
The purpose was to analyze the value of quantitative parameters of DCE-MRI in evaluating micro-infiltration of malignant bone tumors. Methods: Thirty-nine New Zealand white rabbits were used to establish malignant bone tumor models by implanting VX2 tumor fragments into the right tibiae. After three weeks, models were examined by conventional MRI and DCE-MRI; then the right tibiae were cut into sagittal sections and partitioned into histology slices for comparison with microscopic findings. Micro-infiltration groups were selected and the range of infiltration was determined under the microscope, and corresponding DCE images analyzed to obtain the quantitative parameters include Ktrans, Kep, v(e) and v(p), in parenchyma areas, micro-infiltration areas and simple edema areas. One-way ANOVA was used to compare the differences of the parameters between the three areas. Receiver operating characteristic curves (ROCs) were plotted to determine the accuracy of different parameters by area under curves (AUCs). Results: 22 cases (22/39, 56.4%) were included in the micro-infiltration group and the infiltration depth ranged from 1.3 mm to 4.6 mm, with an average depth of 3.2 mm +/- 0.8 mm. The statistical results of quantitative parameters in the three areas were as follows: Ktrans values were (0.494 +/- 0.052), (0.403 +/- 0.049), (0.173 +/- 0.047) min(-1) (p = = 0.000), Kep values were (1.959 +/- 0.65), (1.528 +/- 0.372), (1.174 +/- 0.486) min(-1) (p = =0.000), v(e) values were (0.247 +/- 0.068), (0.283 +/- 0.057), (0.168 +/- 0.062) min(-1) (p = = 0.000), v(p) values were (0.125 +/- 0.036), (0.108 +/- 0.033), (0.098 +/- 0.025) min(-1) (p = = 0.022), respectively. Ktrans and Kep values had significant difference in the three areas after comparing between-groups, respectively. However, there were no significant difference in v(p) values between parenchyma and micro-infiltration areas (p = =0.078), micro-infiltration and simple edema areas (p = =0.315), and v(e) values between parenchyma and micro-infiltration areas (p = =0.056). The v(e) values were higher in parenchyma and micro-infiltration areas then simple edema areas. Ktrans had highest accuracy in differentiating different areas (AUC > 0.9), respectively. Conclusion: Quantitative parameters Ktrans, Kep and v(e) can assess the extent of intramedullary invasion of malignant bone tumors. Ktrans have highest accuracy in differentiating different regions.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 肿瘤学
最新[2023]版:
大类 | 2 区 医学
小类 | 3 区 肿瘤学
JCR分区:
出版当年[2017]版:
Q2 ONCOLOGY
最新[2023]版:
Q2 ONCOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Wuhan Univ, Tongren Hosp, Wuhan Hosp 3, Dept Radiol, Wuhan 430000, Hubei, Peoples R China [2]Qingdao Univ, Affiliated Hosp, Dept Radiol, Qingdao 266003, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21173 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)