高级检索
当前位置: 首页 > 详情页

Development and Internal Validation of a Prediction Model to Estimate the Probability of Left-Ventricular Diastolic Dysfunction in Stable Maintenance Hemodialysis Patients without Clinical Heart Failure

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Shanghai Jiao Tong Univ, Sch Med, Tongren Hosp, Dept Nephrol, Xianxia Rd 1111, Shanghai 200336, Peoples R China [2]Qingdao Univ, Med Coll, Yantai Yuhuangding Hosp, Dept Nephrol, Yantai, Peoples R China [3]Shanghai Jiao Tong Univ, Sch Med, Tongren Hosp, Dept Ultrasound, Shanghai, Peoples R China
出处:
ISSN:

关键词: Prediction model Left-ventricular diastolic dysfunction Maintenance hemodialysis

摘要:
Objective: To develop and internally validate a multivariable prediction model based on simple clinical record data and laboratory tests and to estimate the probability of left-ventricular diastolic dysfunction (LVDD) in stable maintenancehemodialysis (MHD) patients without clinical heart failure. Design: Cross-sectional study. Setting and Participants: In all, 181 patients on MHD without clinical heart failure were eligible from the dialysis center of Tongren Hospital, Shanghai Jiao Tong University School of Medicine between October 2017 and September 2018. Outcomes: LVDD detected by echocardiography. Measurements: We performed multivariable logistic regression using demographic, clinical, and laboratory data to identify predictors of LVDD with internal validation by using 200 bootstrap replications. Results: Overall, 78 out of 181 (43.1%) patients were affected by LVDD. Predictors included in the LVDD Model were high-sensitive cardiac troponin T (OR 5.91 per 1-ln unit; 95% CI 2.17-16.13), B-type natriuretic peptide (OR 2.35 per 1-ln unit; 95% CI 1.14-4.86), and dialysis vintage (OR 1.04 per 1-month; 95% CI 1.01-1.07). The area (AUC) under the receiver operating characteristic curve of the Model was 0.871 (95% CI 0.811-0.932, p < 0.001). The calibration plot showed good agreement between predicted and observed probabilities with a calibration slope of 1.023 and intercept of -0.010. After internal validation, the Model maintained excellent discrimination (AUC 0.858, 95% CI 0.798-0.919) and good calibration (slope of 1.079, 95% CI 1.058-1.097 and intercept of -0.120, 95% CI -0.142 to -0.093). LVDD Model <0.23 can be used to rule out (sensitivity = 87.3%, negative likelihood ratio= 12.7%) and >= 0.44 can be used to rule in (specificity = 87.6%, positive likelihood ratio = 12.4%) echocardiography diagnosed LVDD. Limitation: External validation of the Model will be required. Conclusions: A model using routinely available simple clinical record data and laboratory tests can accurately predict the risk of LVDD in stable MHD patients. The Model and its cutoff values may be useful for early diagnosis and intervention of LVDD.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 3 区 泌尿学与肾脏学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 泌尿学与肾脏学
JCR分区:
出版当年[2017]版:
Q2 UROLOGY & NEPHROLOGY
最新[2023]版:
Q2 UROLOGY & NEPHROLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Shanghai Jiao Tong Univ, Sch Med, Tongren Hosp, Dept Nephrol, Xianxia Rd 1111, Shanghai 200336, Peoples R China
通讯作者:
通讯机构: [1]Shanghai Jiao Tong Univ, Sch Med, Tongren Hosp, Dept Nephrol, Xianxia Rd 1111, Shanghai 200336, Peoples R China [*1]Department of Nephrology, Tongren Hospital Shanghai Jiao Tong University School of Medicine Xianxia Road 1111, Shanghai 200336 (China)
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21279 今日访问量:1 总访问量:1220 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)