高级检索
当前位置: 首页 > 详情页

Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery: An updated meta-analysis

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Key Lab Ophthalmol & Visual Sci, Beijing Tongren Eye Ctr, 1 Dongjiaominxiang Dongcheng Dist, Beijing 100073, Peoples R China [2]Pingdingshan Univ, Med Sch, Pingdingshan, Peoples R China [3]Chinese Peoples Liberat Army, Gen Hosp, Dept Ophthalmol, Beijing, Peoples R China
出处:
ISSN:

关键词: biomaterial cataract hydrophilic hydrophobic intraocular lens Nd:YAG laser capsulotomy posterior capsule opacification

摘要:
Background:Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO.Methods:Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, and intraocular lens. Eligible studies included randomized controlled trials (RCTs), retrospective, and cohort studies.Results:Eleven studies were included in the study with a total of 889 eyes/patients. The overall analysis revealed that hydrophobic intraocular lenses were associated with lower Nd:YAG laser capsulotomy rates than hydrophilic lenses [odds ratio (OR)=0.38, 95% confidence interval (95% CI)=0.16-0.91, P=.029]. Hydrophobic intraocular lenses were also associated with lower subjective PCO score (diff. in means: -1.32, 95% CI=-2.39 to -0.25, P=.015) and estimated PCO score (diff. in means: -2.23; 95% CI, -3.80 to -0.68, P=.005) as compared with hydrophilic lenses. Objective PCO score was similar between lens types. (diff. in means: -0.075; 95% CI, -0.18 to 0.035; P=.182). Pooled analysis found that visual acuity was similar between hydrophobic and hydrophilic intraocular lenses (diff. in means: -0.016; 95% CI, -0.041 to 0.009, P=.208).Conclusion:In general, PCO scores and the rate of Nd:YAG laser capsulotomy were influenced by intraocular lens biomaterial. Lens made of hydrophobic biomaterial were overall superior in lowering the PCO score and the Nd:YAG laser capsulotomy rate, but not visual acuity.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 2 区 医学
小类 | 2 区 医学:内科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
JCR分区:
出版当年[2015]版:
Q2 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q2 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Key Lab Ophthalmol & Visual Sci, Beijing Tongren Eye Ctr, 1 Dongjiaominxiang Dongcheng Dist, Beijing 100073, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Key Lab Ophthalmol & Visual Sci, Beijing Tongren Eye Ctr, 1 Dongjiaominxiang Dongcheng Dist, Beijing 100073, Peoples R China [*1]Beijing Tongren Eye Center, Beijing Key Laboratory of Ophthalmology and Visual Science, Beijing Tongren Hospital, Capital Medical University, 1 Dongjiaominxiang Dongcheng District, Beijing 100073, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23549 今日访问量:0 总访问量:1282 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)