高级检索
当前位置: 首页 > 详情页

Normative Values of Retinal Oxygen Saturation in Rhesus Monkeys: The Beijing Intracranial and Intraocular Pressure (iCOP) Study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Beijing Institute of Ophthalmology,Beijing Tongren Eye Center,Beijing Tongren Hospital,Capital Medical University,Beijing Ophthalmology & Visual Sciences Key Laboratory,Beijing,China [2]Beijing Tongren Eye Center,Beijing Tongren Hospital,Capital Medical University,Beijing Ophthalmology & Visual Sciences Key Laboratory,Beijing,China
出处:
ISSN:

摘要:
Objective To study the normal values of the retinal oxygen saturation in Rhesus monkeys and to evaluated repeatability and reproducibility of retinal oxygen saturation measurements. Methods Eighteen adult Rhesus macaque monkeys were included in this experimental study. An Oxymap T1 retinal oximeter (Oxymap, Reykjavik, Iceland) was used to perform oximetry on all subjects. Global arterial (SaO(2)) and venous oxygen saturation (SvO(2)), arteriovenous difference in SO2 were measured. In the first examination, each eye was imaged three times. At the following two examinations, each eye was imaged once. All examinations were finished in one month. P values were calculated to evaluate the difference between the measurements during three visits by performing an ANOVA. Intra-visit and inter-visit intraclass correlation coefficient (ICC) was determined. Results At baseline, the average SaO(2) and SvO(2) were 89.48 +/- 2.64% and 54.85 +/- 2.18%, respectively. The global A-V difference was 34.63 +/- 1.91%. The difference between the three visits was not significant (p>0.05). The highest A-V difference in SO2 and lowest saturations were found in the inferotemporal quadrant. Intra-session and inter-visit repeatability were both high. For all oxygen saturation parameters, the ICC values of the intra-session repeatability ranged between 0.92 and 0.96. As found previously, a relatively high ICC value for intervisit repeatability also was found for all oxygen saturation measurements, ranging between 0.86 and 0.94, with the lowest values in the infero-nasal quadrant. Conclusions Our study is the first to describe retinal SO2 in healthy Rhesus monkeys. In normal monkey eyes, the reproducibility and repeatability of retinal oximetry oxygen saturation measurements were high in the retinal arterioles and venules. Our results support that Oxymap T1 retinal oximetry is a suitable and reliable technique in monkey studies.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 3 区 生物
小类 | 3 区 综合性期刊
最新[2025]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
JCR分区:
出版当年[2014]版:
Q1 MULTIDISCIPLINARY SCIENCES
最新[2023]版:
Q1 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2014版] 出版当年五年平均 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者机构: [1]Beijing Institute of Ophthalmology,Beijing Tongren Eye Center,Beijing Tongren Hospital,Capital Medical University,Beijing Ophthalmology & Visual Sciences Key Laboratory,Beijing,China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23549 今日访问量:0 总访问量:1282 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)