高级检索
当前位置: 首页 > 详情页

Paraxial Schematic Eye Models for 7-and 14-Year-Old Chinese Children

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing 100730, Peoples R China [2]Anyang Eye Hosp, Anyang, Henan Province, Peoples R China [3]Peking Univ, Sch Publ Hlth, Dept Epidemiol & Hlth Stat, Beijing 100871, Peoples R China [4]Queensland Univ Technol, Sch Optometry & Vis Sci, Kelvin Grove, Qld, Australia [5]Queensland Univ Technol, Inst Hlth & Biomed Innovat, Kelvin Grove, Qld, Australia
出处:
ISSN:

关键词: modeling myopia refraction schematic eyes

摘要:
PURPOSE. To develop three-surface paraxial schematic eyes with different ages and sexes based on data for 7- and 14-year-old Chinese children from the Anyang Childhood Eye Study. METHODS. Six sets of paraxial schematic eyes, including 7-year-old eyes, 7-year-old male eyes, 7-year-old female eyes, 14-year-old eyes, 14-year-old male eyes, and 14-year-old female eyes, were developed. Both refraction-dependent and emmetropic eye models were developed, with the former using linear dependence of ocular parameters on refraction. RESULTS. A total of 2059 grade 1 children (boys 58%) and 1536 grade 8 children (boys 49%) were included, with mean age of 7.1 +/- 0.4 and 13.7 +/- 0.5 years, respectively. Changes in these schematic eyes with aging are increased anterior chamber depth, decreased lens thickness, increased vitreous chamber depth, increased axial length, and decreased lens equivalent power. Male schematic eyes have deeper anterior chamber depth, longer vitreous chamber depth, longer axial length, and lower lens equivalent power than female schematic eyes. Changes in the schematic eyes with positive increase in refraction are decreased anterior chamber depth, increased lens thickness, decreased vitreous chamber depth, decreased axial length, increased corneal radius of curvature, and increased lens power. In general, the emmetropic schematic eyes have biometric parameters similar to those arising from regression fits for the refraction-dependent schematic eyes. CONCLUSIONS. The paraxial schematic eyes of Chinese children may be useful for myopia research and for facilitating comparison with other children with the same or different racial backgrounds and living in different places.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
JCR分区:
出版当年[2013]版:
Q1 OPHTHALMOLOGY
最新[2023]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing 100730, Peoples R China [*1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China, 100730
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing 100730, Peoples R China [4]Queensland Univ Technol, Sch Optometry & Vis Sci, Kelvin Grove, Qld, Australia [5]Queensland Univ Technol, Inst Hlth & Biomed Innovat, Kelvin Grove, Qld, Australia [*1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China, 100730 [*2]School of Optometry & Vision Science and Institute of Health and Biomedical Innovation, Queensland University of Technology, Kelvin Grove, QLD, Australia
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21614 今日访问量:0 总访问量:1239 更新日期:2025-02-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)