高级检索
当前位置: 首页 > 详情页

Visual Acuity and Subfoveal Choroidal Thickness: The Beijing Eye Study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing, Peoples R China [2]Capital Med Univ, Beijing Tongren Hosp, Beijing Inst Ophthalmol, Beijing, Peoples R China [3]Capital Med Univ, Beijing Tongren Hosp, Beijing, Peoples R China [4]Heidelberg Univ, Med Fac Mannheim, Dept Ophthalmol, Heidelberg, Germany
出处:
ISSN:

摘要:
PURPOSE: To examine the association between best corrected visual acuity (BCVA) and subfoveal choroidal thickness. DESIGN: Population-based study. METHODS: The Beijing Eye Study 2011 included 3468 subjects with ages of 50 + years. The participants underwent an ophthalmologic examination including spectral-domain optical coherence tomography with enhanced depth imaging for measurement of choroidal thickness. BCVA was measured as logarithm of the minimal angle of resolution. RESULTS: Of the 3468 participants, choroidal measurements were available for 3233 (93.2%) subjects. In multivariate analysis, better BCVA was significantly associated with thicker subfoveal choroid (P < 0.001) in general and a subfoveal choroid thicker than 30 mu m (P < 0.001) in particular, after adjusting for younger age (P < 0.001), higher level of education (P < 0.001), taller body stature (P < 0.001), higher body mass index (P = 0.005), absence of glaucoma (P = 0.001), absence of diabetic retinopathy (P < 0.001), absence of late-stage age-related macular degeneration (P < 0.001), and axial length shorter than 26.0 mm (P < 0.001) (correlation coefficient r:0.56). If eyes with glaucoma, diabetic retinopathy, late-stage age-related macular degeneration or myopic retinopathy were excluded, better BCVA was still significantly associated with thicker subfoveal choroid (P < 0.001) and subfoveal choroid thicker than 30 mu m (P < 0.001) in multivariate analysis. In a reverse manner, thicker subfoveal choroid was associated with better BCVA (P < 0.001) after adjusting for younger age (P < 0.001), male gender (P < 0.001), longer axial length (P < 0.001), and higher corneal curvature radius (P < 0.001). CONCLUSIONS: Better visual acuity is strongly associated with thicker subfoveal choroid independent of additional factors, such as age, axial length, education level, and major ocular diseases. (C) 2014 by Elsevier Inc. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2013]版:
大类 | 2 区 医学
小类 | 1 区 眼科学
最新[2023]版:
大类 | 1 区 医学
小类 | 1 区 眼科学
JCR分区:
出版当年[2012]版:
Q1 OPHTHALMOLOGY
最新[2023]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2012版] 出版当年五年平均 出版前一年[2011版] 出版后一年[2013版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing, Peoples R China [*1]Beijing Tongren Hosp, Beijing Tongren Eye Ctr, 1 Dong Jiao Min Xiang, Beijing 100730, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21166 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)