高级检索
当前位置: 首页 > 详情页

Nearwork-Induced Transient Myopia and Parental Refractive Error

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Beijing Tongren Eye Ctr, Beijing, Peoples R China [2]Capital Med Univ, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing 100730, Peoples R China [3]Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China [4]Midwestern Univ, Coll Optometry, Glendale, AZ USA [5]SUNY Coll Optometry, Dept Biol & Vis Sci, New York, NY 10036 USA [6]Anyang Eye Hosp, Anyang, Henan, Peoples R China [7]Wenzhou Med Coll, Affiliated Eye Hosp, Wenzhou, Zhejiang, Peoples R China [8]Wenzhou Med Coll, Sch Optometry & Ophthalmol, Wenzhou, Zhejiang, Peoples R China
出处:
ISSN:

关键词: environmental nearwork nearwork-induced transient myopia myopia refractive error

摘要:
Purpose. To investigate the relationship between parental refractive error and the nearwork-induced transient myopia (NITM) characteristics of their children. Methods. Three hundred sixty children (173 boys and 187 girls) aged 6 to 17 years were tested. Initial NITM and its decay time (DT) were assessed objectively (WAM-5500, Grand-Seiko) immediately after binocularly viewing and performing a sustained near task (5 diopters [D]) for 5 minutes, incorporating a cognitive demand with full distance refractive correction in place. The NITM was classified into three categories: low (<0.15 D), moderate (0.15 to 0.30 D), or high (>= 0.30 D), whereas its decay was classified into two categories, namely, complete or incomplete. In addition, the children were divided into three groups based on the number of myopic parents (none, one, or two) and into four groups based on the level of parental myopia (no, low, moderate, or high). Results. Neither paternal nor maternal refractive error was associated with either their children's initial NITM magnitude or its DT in the myopic, emmetropic, or hyperopic groups or the combined group. No significant differences (p > 0.05) in the NITM magnitude, DT, or decay time constant were found as related to the number of myopic parents or level of parental myopia. Multiple odds ratio for incomplete decay of NITM did not change significantly (p > 0.05) with either an increase in number of myopic parents or level of parental myopia. Conclusions. There was no association between parental refractive error and their children's NITM characteristics. This suggests a primary environmental basis for the NITM characteristics in the children. (Optom Vis Sci 2013; 90: 507-516)

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 4 区 医学
小类 | 3 区 眼科学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
JCR分区:
出版当年[2011]版:
Q2 OPHTHALMOLOGY
最新[2023]版:
Q3 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者机构: [2]Capital Med Univ, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing 100730, Peoples R China [3]Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
通讯作者:
通讯机构: [2]Capital Med Univ, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing 100730, Peoples R China [*1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing Ophthalmol & Visual Sci Key Lab, 1 Dong Jiao Min Xiang St, Beijing 100730, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23459 今日访问量:6 总访问量:1282 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)