机构: [1]Beijing Inst Otolaryngol, Beijing 100005, Peoples R China [2]Capital Med Univ, Beijing Tong Ren Hosp, Beijing, Peoples R China [3]Capital Med Univ, Key Lab Otolaryngol Head & Neck Surg, Beijing, Peoples R China [4]Univ Iowa, Dept Commun Sci & Disorders, Iowa City, IA 52242 USA
出处:
ISSN:

关键词: Digital noise reduction hearing aid hearing impairment loudness

摘要:
Background: Transient noise can be disruptive for people wearing hearing aids. Ideally, the transient noise should be detected and controlled by the signal processor without disrupting speech and other intended input signals. A technology for detecting and controlling transient noises in hearing aids was evaluated in this study. Purpose: The purpose of this study was to evaluate the effectiveness of a transient noise reduction strategy on various transient noises and to determine whether the strategy has a negative impact on sound quality of intended speech inputs. Research Design: This was a quasi-experimental study:The study involved 24 hearing aid users. Each participant was asked to rate the parameters of speech clarity, transient noise loudness, and overall impression for speech stimuli under the algorithm-on and algorithm-off conditions. During the evaluation, three types of stimuli were used: transient noises, speech, and background noises. The transient noises included "knife on a ceramic board," "mug on a tabletop," "office door slamming," "car door slamming," and "pen tapping on countertop." The speech sentences used for the test were presented by a male speaker in Mandarin. The background noises included "party noise" and "traffic noise." All of these sounds were combined into five listening situations: (1) speech only, (2) transient noise only, (3) speech and transient noise, (4) background noise and transient noise, and (5) speech and background noise and transient noise. Results: There was no significant difference on the ratings of speech clarity between the algorithm-on and algorithm-off (t-test, p = 0.103). Further analysis revealed that speech clarity was significant better at 70 dB SLP than 55 dB SPL (p < 0.001). For transient noise loudness: under the algorithm-off condition, the percentages of subjects rating the transient noise to be somewhat soft, appropriate, somewhat loud, and too loud were 0.2, 47.1, 29.6, and 23.1%, respectively. The corresponding percentages under the algorithm-on were 3.0, 72.6, 22.9, and 1.4%, respectively. A significant difference on the ratings of the transient noise loudness was found between the algorithm-on and algorithm-off (t-test, p < 0.001). For overall impression for speech stimuli: under the algorithm-off condition, the percentage of subjects rating the algorithm to be not helpful at all, somewhat helpful, helpful, and very helpful for speech stimuli were 36.5, 20.8, 33.9, and 8.9%, respectively. Under the algorithm-on condition, the corresponding percentages were 35.0, 19.3, 30.7, and 15.0%, respectively. Statistical analysis revealed there was a significant difference on the ratings of overall impression on speech stimuli. The ratings under the algorithm-on condition were significantly more helpful for speech understanding than the ratings under algorithm-off (t-test, p < 0.001). Conclusions: The transient noise reduction strategy appropriately controlled the loudness for most of the transient noises and did not affect the sound quality, which could be beneficial to hearing aid wearers.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 4 区 医学
小类 | 4 区 耳鼻喉科学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 听力学与言语病理学 4 区 耳鼻喉科学
JCR分区:
出版当年[2010]版:
Q3 OTORHINOLARYNGOLOGY
最新[2023]版:
Q3 OTORHINOLARYNGOLOGY Q3 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者机构: [1]Beijing Inst Otolaryngol, Beijing 100005, Peoples R China [2]Capital Med Univ, Beijing Tong Ren Hosp, Beijing, Peoples R China [3]Capital Med Univ, Key Lab Otolaryngol Head & Neck Surg, Beijing, Peoples R China
通讯作者:
通讯机构: [1]Beijing Inst Otolaryngol, Beijing 100005, Peoples R China [2]Capital Med Univ, Beijing Tong Ren Hosp, Beijing, Peoples R China [3]Capital Med Univ, Key Lab Otolaryngol Head & Neck Surg, Beijing, Peoples R China [*1]Beijing Inst Otolaryngol, 17 Hou Gou Lane, Beijing 100005, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)