Insertion force in manual and robotic corneal suturing

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Beijing Univ Aeronaut & Astronaut, Sch Mech Engn & Automat, Dept Mech Design, Beijing 100191, Peoples R China [2]Beijing Inst Ophthalmol, Beijing, Peoples R China
出处:
ISSN:

关键词: corneal suturing insertion force micro-forceps manipulator insertion trajectory

摘要:
Background Due to differences in corneal grafting microsurgery between manual and robotic suturing, new challenges have arisen in testing the insertion force and torque of corneal tissue acting on suturing needles in order to guarantee successful completion of surgical procedures. Methods In order to measure the force during the insertion operation, from the needle entering the cornea through the entry point until the puncturing of the exit point along the circular trajectory, a force measurement system was established, including fresh porcine cornea, a corneal-suturing robot, a circular needle, a micro-forceps manipulator with a force transducer, a computer with a data acquisition board and a medical microscope. The force values in the needle coordinate frames were obtained on the basis of a sensor coordinate frame through D-H coordinate transformation, and an index is proposed here to evaluate the insertion performance. Experiments on both manual and robotic suturing were carried out for comparison. Results The scale and changes of the needle insertion force were obtained using two different suturing methods. The maximal tangent force in robotic suturing is a little larger than in manual suturing, and the maximal resultant force in robotic suturing is somewhat smaller. Although the difference is not very significant, robotic suturing performs in a more stable way. Moreover, the performance evaluation index M-dmax (the maximum of square root of the quadratic sum of torque components M-OX and M-OY) in robotic suturing is much smaller than that in manual suturing. Conclusions The force measurement system has been verified to be feasible through experimentation. Compared with conventional manual surgery, robotic suturing has some advantages: more stable suturing, smaller distortion torque and fewer invasions to the corneal tissue, showing that its application in minimally invasive surgery is practical. Copyright (C) 2011 John Wiley & Sons, Ltd.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 4 区 医学
小类 | 4 区 外科
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 外科
JCR分区:
出版当年[2010]版:
Q3 SURGERY
最新[2023]版:
Q2 SURGERY

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者机构: [1]Beijing Univ Aeronaut & Astronaut, Sch Mech Engn & Automat, Dept Mech Design, Beijing 100191, Peoples R China
通讯作者:
通讯机构: [1]Beijing Univ Aeronaut & Astronaut, Sch Mech Engn & Automat, Dept Mech Design, Beijing 100191, Peoples R China [*1]Beijing Univ Aeronaut & Astronaut, Sch Mech Engn & Automat, Dept Mech Design, 37 Xueyuan Rd, Beijing 100191, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:25491 今日访问量:0 总访问量:1499 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)