Comparative study of retinal nerve fibre layer measurement by RTVue OCT and GDx VCC

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China [2]Beijing Shi Jing Shan Hosp, Beijing, Peoples R China
出处:
ISSN:

摘要:
Aim To evaluate the diagnostic performances and correlations of retinal nerve fibre layer (RNFL) thickness measured by RTVue OCT and GDx variable corneal compensation (VCC). Methods The total and regional RNFL thickness were measured by RTVue OCT and GDx VCC in 62 normal eyes and 72 glaucomatous eyes of Chinese subjects. The RNFL thickness profiles of normal and glaucomatous eyes by RTVue OCT are plotted. Correlations of RNFL thickness measured by RTVue OCT and GDx VCC were assessed using the Pearson correlation. The discriminating abilities of the two techniques for detection of glaucoma were compared by the area under the receiver operating characteristic curves (AUC). Results RTVue OCT demonstrated double hump patterns in the RNFL profiles. In both normal and glaucomatous subjects, the peaks were located in the superotemporal (ST) and inferotemporal (IT) regions, and the troughs were located at the nasal (NU+ NL) and temporal (TU + TL) regions. Despite poor agreement, a high correlation (r=0.821) was found between the mean RNFL measurements by RTVue OCT and GDx VCC. For RTVue OCT, the highest AUCs were mean RNFL (AUC=0.914) and inferior mean RNFL (AUC=0.909). The nerve fibre indicator (AUC=0.856) and inferior RNFL (AUC=0.852) achieved the highest AUCs among all the GDx VCC measurements. The mean RNFL in RTVue OCT had the greatest AUC in the two devices. There was a significant difference in comparing the AUCs of the mean RNFL thickness obtained by RTVue OCT and GDx VCC (p=0.009). Conclusions Although there were absolute value differences in RNFL thickness, a high correlation was observed between RTVue OCT and GDx VCC. RTVue OCT shows a reasonable ability to distinguish normal from glaucomatous eyes.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2010]版:
大类 | 3 区 医学
小类 | 2 区 眼科学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
JCR分区:
出版当年[2009]版:
Q1 OPHTHALMOLOGY
最新[2023]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2009版] 出版当年五年平均 出版前一年[2008版] 出版后一年[2010版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China [*1]1 Dongjiao Min Xiang, Beijing 100730, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:25463 今日访问量:4 总访问量:1498 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)