高级检索
当前位置: 首页 > 详情页

Optical Coherence Tomography Optic Nerve Head Morphology in Myopia I: Implications of Anterior Scleral Canal Opening Versus Bruch Membrane Opening Offset

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Legacy Res Inst, Devers Eye Inst, Opt Nerve Head Res Lab, Portland, OR 97208 USA [2]Legacy Res Inst, Discoveries Sight Res Labs, Devers Eye Inst, Portland, OR 97208 USA [3]Seoul Natl Univ, Seoul Natl Univ Hosp, Dept Ophthalmol, Coll Med, Seoul, South Korea [4]Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing Inst Ophthalmol, Beijing, Peoples R China [5]Catholic Univ Korea, Med Coll, Dept Ophthalmol & Visual Sci, Seoul, South Korea [6]Natl Univ Singapore, Dept Biomed Engn, Ophthalm Engn & Innovat Lab, Singapore, Singapore [7]Dalhousie Univ, Dept Ophthalmol & Visual Sci, Halifax, NS, Canada
出处:
ISSN:

摘要:
PURPOSE: To measure the magnitude and direction of anterior scleral canal opening (ASCO) offset relative to the Bruch membrane opening (BMO) (ASCO/BMO offset) to characterize neural canal obliqueness and minimum cross-sectional area (NCMCA) in 69 highly myopic and 138 healthy, age-matched, control eyes. DESIGN: Cross-sectional study. METHODS: Using optical coherence tomography (OCT) scans of the optic nerve head (ONH), BMO and ASCO were manually segmented and their centroids and size and shape were calculated. ASCO/BMO offset magnitude and direction were measured after projecting the ASCO/BMO centroid vector onto the BMO plane. Neural canal axis obliqueness was defined as the angle between the ASCO/BMO centroid vector and the vector perpendicular to the BMO plane. NCMCA was defined by projecting BMO and ASCO points onto a plane perpendicular to the neural canal axis and measuring their overlapping area. RESULTS: ASCO/BMO offset magnitude was greater (highly myopic eyes 264.3 +/- 131.1 mu m; healthy control subjects 89.0 +/- 55.8 mu m, P < .001, t test) and ASCO centroid was most frequently nasal relative to BMO centroid (94.2% of eyes) in the highly myopic eyes. BMO and ASCO areas were significantly larger (P < .001, t test), NCMCA was significantly smaller (P < .001), and all 3 were significantly more elliptical (P <=.001) in myopic eyes. Neural canal obliqueness was greater in myopic (65.17 degrees +/- 14.03 degrees) compared with control eyes (40.91 degrees +/- 16.22 degrees; P < .001, t test). CONCLUSIONS: Our data suggest that increased temporal displacement of BMO relative to the ASCO, increased BMO and ASCO area, decreased NCMCA, and increased neural canal obliqueness are characteristic components of ONH morphology in highly myopic eyes. (C) 2020 Elsevier Inc. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
最新[2023]版:
大类 | 1 区 医学
小类 | 1 区 眼科学
JCR分区:
出版当年[2018]版:
Q1 OPHTHALMOLOGY
最新[2023]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者机构: [1]Legacy Res Inst, Devers Eye Inst, Opt Nerve Head Res Lab, Portland, OR 97208 USA [2]Legacy Res Inst, Discoveries Sight Res Labs, Devers Eye Inst, Portland, OR 97208 USA [3]Seoul Natl Univ, Seoul Natl Univ Hosp, Dept Ophthalmol, Coll Med, Seoul, South Korea
共同第一作者:
通讯作者:
通讯机构: [1]Legacy Res Inst, Devers Eye Inst, Opt Nerve Head Res Lab, Portland, OR 97208 USA [2]Legacy Res Inst, Discoveries Sight Res Labs, Devers Eye Inst, Portland, OR 97208 USA [*1]Legacy Devers Eye Inst, Opt Nerve Head Res Lab, 1225 NE 2nd Ave, Portland, OR 97208 USA
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)