机构:[1]Department of General Surgery, Tongren Hospital, Beijing 100730.首都医科大学附属同仁医院
出处:
ISSN:
摘要:
To evaluate the diagnostic value of MRCP in finding positions and causes of obstructive jaundice.Fourty-two patients with obstructive jaundice received MRCP examination. All patients were finally onfirmed operatively.The correct diagnostic rate of finding obstructive positions in MRCP was 100% and the correct rate of finding obstructive causes 78.57%. MRCP combined with MRI raised the accuracy of diagnosis of obstructive causes. (90.48%). All pathogenic changes have their own characteristics.MRCP in diagnosing obstructive jaundice is quite effective and safe because of its clear pictures without use of contrast medium and no complications.
语种:
中文
PubmedID:
第一作者:
第一作者机构:[1]Department of General Surgery, Tongren Hospital, Beijing 100730.
推荐引用方式(GB/T 7714):
Xia F,Li J,Chen F,等.The value of MR cholangiopancreatograghy in diagnosis of obstructive jaundice[J].Chinese Journal of Surgery.1999,37(4):219-21.