高级检索
当前位置: 首页 > 详情页

Optical coherence tomography angiography characteristics of optic disc melanocytoma.

文献详情

资源类型:
Pubmed体系:
机构: [1]Beijing Tongren Eye Center, Beijing Key Laboratory of Intraocular Tumor Diagnosis and Treatment, Medical Artificial Intelligence Research and Verification Laboratory of the Ministry of Industry and Information Technology, Beijing Tongren Hospital, Capital Medical University, Beijing, China
出处:

摘要:
Optic disc melanocytoma (ODMC) was a benign pigmented intraocular tumor with the rare potential malignant transformation. This study was designed to evaluate tumor vasculature with optical coherence tomography angiography (OCTA) in ODMC.Eyes of healthy individuals in a control group and of patients with ODMC were imaged by OCTA systems operating at 840 nm wavelengths and examined. The main outcome measures were OCTA images, qualitative evaluation of optic disc and tumor vasculature, quantitative vascular density (VD) and perfusion density (PD).One eye of ten normal volunteers and ten patients with ODMC were imaged. Eyes affected by ODMC as compared to the eyes of the control group (all P < 0.05). The healthy optic disc had radially-oriented vessels within the retina on OCTA. Optic disc melanocytoma was characterized by globular, demonstrated tortuous blood vessels, uneven thickness, and relatively disorganized intratumoral vasculature. The VD and PD within ODMC were significantly higher (12.360% ± 4.175, 0.316% ± 0.119%, P < 0.0001) than in normal optic discs (4.160% ± 2.290, 0.102% ± 0.0, 56%, P < 0.0001). No significant differences were established of the VD and PD in each single measurement zone (P > 0.05) between the ODMC and the control eyes. At 840 nm, OCTA could provide sufficient visualization of the tumor vasculature and better penetration through thicker tumors. The full thickness was visualized even in thicker tumors and highly pigmented lesions (> 2 mm). Interpretable OCTA images were obtained in 96% of the participants in whom imaging was attempted.OCTA may provide a noninvasive, safe, and efficient technique for evaluating a variety of neoplasms including the growth and vascularity in ODMC. OCTA could facilitate the evaluation of the vascular abnormalities of tumors and the effect of melanin on the penetration of the OCTA beam was not significant.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
第一作者:
第一作者机构: [1]Beijing Tongren Eye Center, Beijing Key Laboratory of Intraocular Tumor Diagnosis and Treatment, Medical Artificial Intelligence Research and Verification Laboratory of the Ministry of Industry and Information Technology, Beijing Tongren Hospital, Capital Medical University, Beijing, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:25463 今日访问量:0 总访问量:1498 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)