Diagnosis of obstructive sleep apnea using a bio-radar contact-free system compared with an established HST device in older adults

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Respiratory and Critical Care Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China [2]Department of Respiratory and Critical Care Medicine, Putuo District Liqun Hospital, Shanghai, China [3]Institute of Respiratory Medicine, Shanghai Jiao Tong University School of Medicine, Shanghai, China [4]Department of Respiratory and Critical Care Medicine, Tongren Hospital Affiliated With Wuhan University, The Third Hospital of Wuhan, Wuhan, China
出处:
ISSN:

摘要:
To compare a bio-radar contact-free monitoring device in diagnosing obstructive sleep apnea (OSA) in older people with an established home sleep apnea testing system (HST).A bio-radar contact-free monitoring device (OrbSense+).An established HST, Alice NightOne.Fifty-three out of 63 recruited subjects were included in the final analysis. Seventy-two percent were male (age 72 ± 9 years; body mass index 31.05 ± 5.56 kg/m2).An observational, prospective study.Intraclass correlation coefficient (ICC), Bland-Altman analysis, and receiver operating characteristic analysis.None.Both 45 (84.91%) were diagnosed with OSA by Alice NightOne (average respiratory event index = 21.23 events/h) and by OrbSense+ (average respiratory event index = 25.98 events/h). Respiratory event index and oxygen desaturation index obtained by Alice NightOne and OrbSense+ were highly correlated, with ICC of 0.93 and 0.88, respectively. The Bland-Altman plot comparing the means showed good agreement between the 2 diagnostic techniques. With more than 5 respiratory events per hour as the standard for OSA diagnosis, OrbSense+ had a sensitivity of 100% and a specificity of 100% in diagnosis of OSA (P < .0001). With more than 15 respiratory events per hour as the standard for OSA diagnosis, OrbSense+ was found to have a sensitivity of 100% and a specificity of 86.96% in diagnosis of OSA (P < .0001).None.The bio-radar sleep monitoring device is a reasonably accurate home sleep apnea test for use in older patients.Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 2 区 医学
小类 | 3 区 临床神经病学
最新[2025]版:
大类 | 2 区 医学
小类 | 3 区 临床神经病学
JCR分区:
出版当年[2021]版:
Q2 CLINICAL NEUROLOGY
最新[2024]版:
Q2 CLINICAL NEUROLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Department of Respiratory and Critical Care Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China [3]Institute of Respiratory Medicine, Shanghai Jiao Tong University School of Medicine, Shanghai, China [4]Department of Respiratory and Critical Care Medicine, Tongren Hospital Affiliated With Wuhan University, The Third Hospital of Wuhan, Wuhan, China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Respiratory and Critical Care Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China [3]Institute of Respiratory Medicine, Shanghai Jiao Tong University School of Medicine, Shanghai, China [*1]Department of Respiratory and Critical Care Medicine, Ruijin Hospital, Shanghai Jiao Tong University school of Medicine, Shanghai 200025, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:28518 今日访问量:0 总访问量:1589 更新日期:2025-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)