New-designed 3D printed surgical guide promotes the accuracy of endodontic microsurgery: a study of 14 upper anterior teeth

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Endodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210008, Jiangsu, People’s Republic of China. [2]Nanjing Tongren Hospital, Nanjing 210008, Jiangsu, People’s Republic of China. [3]Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong 226000, Jiangsu, People’s Republic of China.
出处:
ISSN:

摘要:
We aimed to design a novel three-dimensional (3D) printed surgical guide and evaluate its accuracy in assisting endodontic microsurgeries. A new 3D printed surgical guide was designed by computer-aided design and computer-aided manufacturing (CAD/CAM) technology and applied to 7 patients who underwent endodontic microsurgeries of upper anterior teeth from 2020.01 to 2020.12 as the experimental group. 7 patients who suffered from endodontic microsurgeries operated by the same surgeon without using the surgical guide from 2019.01 to 2019.12 were selected as the control group. Cone beam computed tomography (CBCT) was performed more than 12 months after operation, and the accuracy of apical resection was compared between the two groups. The accuracy of the microsurgery focused on the length and angle of the root apical resection. In the study, CBCT data and oral digital scanning data were used to reconstruct 3D models of periapical lesions with soft and hard tissue information, based on which we designed the new 3D printed surgical guides. The guides were successfully applied to the apectomy in endodontic microsurgeries. The deviation of the apical resection length of the experimental group (0.467 ± 0.146 mm) was better than that of the control group (1.743 ± 0.122 mm) (P < 0.0001), and the deviation of the apical resection angle of the experimental group (9.711 ± 3.593°) was significantly less than that of the control group (22.400 ± 3.362°) (P < 0.0001). The 3D-printed surgical guide could effectively guide endodontic microsurgery and improve its accuracy by fixing both the position and the angle of apectomy. The new type of surgical guide could accurately localize the root apex and guide the apical resection.© 2023. Springer Nature Limited.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
最新[2025]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
JCR分区:
出版当年[2021]版:
Q2 MULTIDISCIPLINARY SCIENCES
最新[2024]版:
Q1 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2024版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Department of Endodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210008, Jiangsu, People’s Republic of China.
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:28514 今日访问量:0 总访问量:1589 更新日期:2025-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)