高级检索
当前位置: 首页 > 详情页

Plasma levels of Sirtuin 7 are decreased in patients with essential hypertension

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Heart Center and Beijing Key Laboratory of Hypertension, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China [2]Department of Geriatrics, Beijing Tongren Hospital, Capital Medical University, Beijing, China [3]Department of Cardiology, Beijing Chaoyang Hospital, Capital Medical University. Beijing, China [4]Medical Research Center, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
出处:
ISSN:

关键词: Sirtuin 7 Hypertension Receiver operating characteristics Systolic blood pressure Cross-sectional study

摘要:
Sirtuin 7 (SIRT7), as a nicotinamide adenine dinucleotide-dependent protein/histone deacetylase, has been implicated in the pathogenesis of cardiovascular diseases. However, whether SIRT7 is related to hypertension remains largely unclear. Thus, this study aims to explore the effects and correlation between SIRT7 and hypertension.A total of 72 patients with essential hypertension and 82 controls with non-hypertension were recruited at Beijing Tongren Hospital Affiliated with Capital Medical University from July 2022 to June 2023. Plasma SIRT7 expression was measured using enzyme-linked immunosorbent assay analysis. Clinical baseline characteristics, laboratory measurements, echocardiographic data, and medical therapy were collected.Plasma levels of SIRT7 were lower in hypertensive patients compared with non-hypertensive patients [0.97 (0.58-1.30) vs. 1.24 (0.99-1.46) ng/mL, P < 0.001, respectively]. Furthermore, compared with the low SIRT7 group, there were lower levels of systolic blood pressure, hyperlipidemia, and the ultrasonic electrocardiogram parameters left ventricular end-diastolic diameter and left atrial in diastole in the high SIRT7 group (P < 0.05, respectively). More importantly, multivariate logistic regression analyses indicated that plasma SIRT7 was a predictor of hypertension [OR: 0.06, 95 % CI (0.02-0.19), P < 0.001]. Receiver operating characteristics curve analysis revealed that the optimal cutoff value for plasma SIRT7 levels in detecting hypertension was determined as 0.85 ng/mL with a sensitivity of 73.6 % and a specificity of 89.0 %. The area under the curve for SIRT7 was 0.821 (95 % CI, 0.751-0.878; P < 0.001).Plasma levels of SIRT7 are decreased in patients with essential hypertension, implying its potential as a biomarker for diagnosing essential hypertension..Copyright © 2024 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学实验技术
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 医学实验技术
JCR分区:
出版当年[2022]版:
Q2 MEDICAL LABORATORY TECHNOLOGY
最新[2024]版:
Q2 MEDICAL LABORATORY TECHNOLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Heart Center and Beijing Key Laboratory of Hypertension, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
共同第一作者:
通讯作者:
通讯机构: [1]Heart Center and Beijing Key Laboratory of Hypertension, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China [3]Department of Cardiology, Beijing Chaoyang Hospital, Capital Medical University. Beijing, China [4]Medical Research Center, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:29058 今日访问量:0 总访问量:1619 更新日期:2025-10-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)