高级检索
当前位置: 首页 > 详情页

Assessment of the Corneal Biomechanical Features of Sturge-Weber Syndrome Using Dynamic Ultrahigh-speed Scheimpflug Imaging

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Ophthalmology, West China Hospital, Sichuan University, Chengdu, China [2]West China School of Medicine, Sichuan University, Chengdu, Sichuan, China [3]Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, China [4]School of Life Science and Engineering, Southwest Jiaotong University, Chengdu, Sichuan, China [5]Georgia State University, Atlanta, GA.
出处:
ISSN:

摘要:
To evaluate the corneal biomechanical characteristics of eyes with Sturge-Weber syndrome (SWS) secondary glaucoma (SSG) by analyzing corneal biomechanical parameters obtained using the Corneal Visualization Scheimpflug Technology instrument (Corvis ST).In patients with SWS, eyes affected by SSG were designated as the SSG group while the contralateral eyes were designated as the SWS contralateral group (SC group). Patients from the myopia clinic served as the control group. Dynamic corneal response parameters (DCRs) including the stress-strain index (SSI)-a critical material stiffness parameter that excludes interference from IOP and central corneal thickness (CCT)-were analyzed.For CCT, no significant difference was observed between the SSG and SC groups. However, significant differences were found between the SSG and control groups and between the SC and control groups. Parameters such as HC Time, A1 Deformation Amp., A2 Deformation Amp., length of Whole Eye Movement (WEM), DA Ratio Max (2 mm), PachySlope, DA Ratio Max (1 mm), and ARTh showed significant differences between the SSG group and control group. In the SSG group, 4 of night eyes had an SSI of less than 0.85.Some DCRs indicated a stiffer cornea in the SSG group, possibly due to a thicker cornea in this group. On analyzing SSI, it was found that corneal material properties change, becoming less stiff in some of the patients with SSG. In conclusion, our study provides a preliminary exploration of the biomechanical properties of SWS secondary glaucoma.Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
JCR分区:
出版当年[2022]版:
Q2 OPHTHALMOLOGY
最新[2024]版:
Q2 OPHTHALMOLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Department of Ophthalmology, West China Hospital, Sichuan University, Chengdu, China [2]West China School of Medicine, Sichuan University, Chengdu, Sichuan, China [3]Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:29032 今日访问量:0 总访问量:1619 更新日期:2025-10-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)