文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ SSCI

机构: [1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Beijing Key Laboratory of Ophthalmology & Visual Sciences, Capital Medical University, Beijing, China [2]Wilmer Eye Institute, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
出处:
ISSN:

关键词: Virtual reality pupil tracking strabismus cover tests

摘要:
To explore the accuracy of VR technology for strabismus screening.In this cross-sectional study, a total of 191 subjects were included. Examinations included VR technology based on infrared, the cover-uncover test, and the prism alternating cover test (PACT) at various gaze positions, specifically at distances of 33 cm and 6 m. The accuracy of VR in diagnosing strabismus and quantifying the degree of strabismus was evaluated by comparing the VR results to the average outcomes of manual examinations conducted by the two physicians, considered the gold standard.A total of 88 healthy individuals, 81 exotropia patients, 17 esotropia patients, and five vertical strabismus patients were included in this study, and each subject was screened for less than 2 min. The sensitivity of VR for screening strabismus was 80.3% and the specificity was 80%, displaying moderately consistent with the manual results (Kappa = 0.598, p < .001). The sensitivity for diagnosing exotropia was 76.5% and the specificity was 91.8%, also showing strong agreement with the manual results (Kappa = 0.695, p < 0.001). The sensitivity for diagnosing esotropia was 94.1% and the specificity was 95.4%, with strong agreement with the manual results (Kappa = 0.755, p < .001). The sensitivity for diagnosing vertical strabismus was 80% and the specificity was 98.9%, with strong agreement with manual results (Kappa = 0.719, p < .001). For ocular deviation angle calculations, intraclass correlation coefficient (ICC) was used to compare the agreement between VR and manual results. It showed moderately agreement for exotropia in the near mode (ICC = 0.587, range, -0.036-0.826) and less agreement for exotropia in far mode (ICC = 0.349, range, -0.042-0.615). ICC was in good agreement (ICC = 0.701, range, 0.358-0.879) for the esotropic far mode results (6 m) and not statistically significant for the esotropic near mode results (33 cm). ICC was in good agreement (ICC = 0.606, range = -0.143 to 0.946) for the vertical-near-mode results (33 cm) and not statistically significant for the vertical-far-mode results (6 m).This novel technique for strabismus screening, which utilizes virtual reality technology, enables quick, precise, and straightforward diagnosis of strabismus. It has also shown notable efficacy in accurately measuring the angle of deviation in cases of exotropia.© The Author(s) 2024.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 3 区 卫生保健与服务 3 区 卫生政策与服务 3 区 公共卫生、环境卫生与职业卫生 4 区 医学:信息
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 卫生保健与服务 3 区 卫生政策与服务 3 区 公共卫生、环境卫生与职业卫生 4 区 医学:信息
JCR分区:
出版当年[2022]版:
Q1 HEALTH POLICY & SERVICES Q2 HEALTH CARE SCIENCES & SERVICES Q2 MEDICAL INFORMATICS Q2 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH
最新[2024]版:
Q1 HEALTH CARE SCIENCES & SERVICES Q1 HEALTH POLICY & SERVICES Q1 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH Q3 MEDICAL INFORMATICS

影响因子: 最新[2024版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Beijing Key Laboratory of Ophthalmology & Visual Sciences, Capital Medical University, Beijing, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:29032 今日访问量:0 总访问量:1619 更新日期:2025-10-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)