高级检索
当前位置: 首页 > 详情页

Genetic Spectrum and Genotype-Phenotype Correlations in a Chinese Cohort With Nanophthalmos With Secondary Angle-Closure Glaucoma

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Beijing Tongren Eye Center Research Ward, Beijing Tongren Hospital, Beijing Institute of Ophthalmology, Beijing Ophthalmology & Visual Sciences Key Laboratory, Capital Medical University, Beijing, China.
出处:
ISSN:

关键词: nanophthalmos with secondary angle-closure glaucoma (NSACG) genotypephenotype correlations whole-exome sequencing

摘要:
The purpose of this study was to explore the genetic and clinical features of nanophthalmos with secondary angle-closure glaucoma (NSACG) in a Chinese cohort. This was a prospective cross-sectional study of 157 eyes from 88 Chinese patients with NSACG.The participants underwent ocular and systemic examinations and whole-exome sequencing. The main outcome measures were pathogenic genetic variants, axial length (AL), refractive spherical equivalent (SE), vitreous chamber depth (VCD), white-to-white (WTW), radius of corneal curvature (flat and steep K: K1 and K2), anterior chamber depth (ACD), lens vault (LV), lens thickness (LT), extent of angle closure, anterior segment crowding value, retinal nerve fiber layer (RNFL) thickness, central subfield thickness (CST) in macular, cup-to-disc ratio (C/D), mean defect in visual field, and onset age of angle-closure glaucoma (ACG).Seventy-eight variants (51.14%) were identified in 45 patients, including 20 in PRSS56 (44.44%) and 14 in MFRP (31.11%) with autosomal recessive (AR) inheritance, 8 in MYRF (17.78%), and 3 in TMEM98 (6.6%) with autosomal dominant (AD) inheritance. Individuals with genetic diagnosis were associated with shorter AL, higher SE, larger K1 and K2, shallower ACD, greater angle closure extent, larger LT/AL, shorter VCD, and higher incidence of retinal detachment. Compared with AR cases, patients with AD showed younger ACG onset, longer AL, lower SE, smaller K1 and K2, longer VCD, thinner CST of the macula, and more severe visual field defects.Among Chinese patients with NSACG, PRSS56 and MFRP were the predominant AR variants, whereas MYRF and TMEM98 were the main AD variants. Genetic diagnosis exhibited shorter AL and a more crowded anterior segment, leading to accelerated glaucoma progression. The faster glaucoma progression in AD cases highlights the need for early intervention.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2025]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
JCR分区:
出版当年[2023]版:
Q1 OPHTHALMOLOGY
最新[2024]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版] 出版后一年[2024版]

第一作者:
第一作者机构: [1]Beijing Tongren Eye Center Research Ward, Beijing Tongren Hospital, Beijing Institute of Ophthalmology, Beijing Ophthalmology & Visual Sciences Key Laboratory, Capital Medical University, Beijing, China.
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:28515 今日访问量:0 总访问量:1589 更新日期:2025-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)