高级检索
当前位置: 首页 > 详情页

Efficacy of cylindrical annular refractive elements (CARE) spectacle lenses in slowing myopia progression over 2 years

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin, P.R. China [2]Tianjin Eye Hospital Optometric Center, Tianjin, P.R. China. [3]Beijing Tongren Vision Care, Beijing Tongren Hospital, Capital Medical University, Beijing, P.R. China. [4]He Eye Specialist Hospital, Shenyang, Liaoning Province, P.R. China. [5]ZEISS Vision Care, Aalen, Germany, Carl Zeiss Vision International GmbH, Aalen, Germany. [6]ZEISS Vision Care, Carl Zeiss Vision (Guangzhou) Ltd., Guangzhou, P.R. China. [7]School of Optometry and Vision Science, Faculty of Medicine and Health, University of New South Wales, Sydney, Australia.
出处:
ISSN:

关键词: myopia progression myopia control spectacle lenses cylindrical annular refractive elements

摘要:
To evaluate over a 2-year period, the efficacy of spectacle lenses incorporating cylindrical annular refractive elements (CARE) in slowing myopia progression compared to single vision (SV) spectacle wear.Double-masked, multi-center, randomized clinical trial.A total of 240 Chinese children aged 6-13 yrs, spherical equivalent refractive error (SE) -0.75D to -5.00D were randomized to one of three groups of SV spectacle lens, CARE spectacles (7mm central clear zone surrounded by treatment zone incorporating CARE with mean surface power +4.6D), and CARE S (9mm central clear zone surrounded by treatment zone comprising CARE with mean surface power +3.8D). Cycloplegic SE and axial length (AL) were measured at six-monthly intervals.Progression (mean ± SD) in SV wearing eyes after 24 months of SPL wear was -1.15 ± 0.63 D/ 0.59 ± 0.26 mm with SV for SE/AL, respectively. In comparison, myopia progression was significantly slower with both CARE-0.73 ± 0.63D/ 0.40 ± 0.26 mm, p<.0001 and CARE S -0.80 ± 0.56D/ 0.44 ± 0.25 mm, p<.0001. Progression did not differ significantly between CARE lenses. Adjusting for site, group, age, gender and baseline value at 24 months, CARE showed an absolute difference in SE of 0.44D (95% CI: 0.21 to 0.66D) and CARE S 0.41D (95% CI: 0.21 to 0.66D) compared to SV. AL reduction was 0.20 mm (95% CI: 0.10 to 0.30mm) with CARE and 0.17 mm (0.07 to 0.26mm) with CARE S as compared to SV.Over a 2-year period, lenses incorporating CARE significantly slowed myopia progression as compared to SV lenses.Copyright © 2025. Published by Elsevier Inc.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2025]版:
大类 | 1 区 医学
小类 | 1 区 眼科学
最新[2025]版:
大类 | 1 区 医学
小类 | 1 区 眼科学
JCR分区:
出版当年[2023]版:
Q1 OPHTHALMOLOGY
最新[2024]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版] 出版后一年[2024版]

第一作者:
第一作者机构: [1]Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin, P.R. China [2]Tianjin Eye Hospital Optometric Center, Tianjin, P.R. China.
通讯作者:
通讯机构: [1]Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin, P.R. China [2]Tianjin Eye Hospital Optometric Center, Tianjin, P.R. China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:28514 今日访问量:5 总访问量:1589 更新日期:2025-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)