高级检索
当前位置: 首页 > 详情页

Correlation between corneal biomechanical and tomographic parameters in cataract patients

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China [2]Beijing Tongren Hospital, Capital Medical University [3]Beijing Institute of Ophthalmology, Beijing 100005, China
出处:
ISSN:

关键词: corneal biomechanical parameters corneal tomography cataract

摘要:
AIM: To investigate the relationship between preoperative corneal biomechanical properties and corneal tomographic properties in cataract patients. METHODS: The study consisted of 59 eyes of 30 participants who were diagnosed as cataract in Peking University Third Hospital between September 2019 and November 2019. Stepwise multivariable linear regression analysis was calculated to determine the relationship between corneal biomechanical parameters and tomographic parameters. The patients were classified into three groups of with the rule (WTR) astigmatism, against the rule astigmatism and oblique astigmatism. And the differences in corneal parameters among different groups were compared. RESULTS: There were significant differences in the first applanation time (A1T), the first applanation length (A1L), corneal velocity during the first applanation (Vin), the second applanation time (A2T), highest concavity (HC) radius, displacement amount (DA), DA ratio, stiffness parameter A1 (SPA1) and integrated radius (IR) between oblique astigmatism patients and the other two groups. Total corneal steep meridian (K2) was negatively associated with A1L, A1T and corneal velocity during the second applanation (Vout). Patients with higher anterior corneal curvature had lower HC radius and central corneal thickness (CCT; P=0.001 and 0.006, respectively), while the Ambrosio relational thickness to the horizontal profile (ARTh) was higher than those with lower anterior corneal curvature (P=0.009). CONCLUSION: The study reveals that the elasticity of corneal collagen fibers is greater, but the viscoelasticity of cornea is smaller in patients with oblique astigmatism. There is no significant difference in ARTh between patients with different types of astigmatism, that is, the corneal biomechanical specificity of oblique astigmatism group is probably not caused by corneal thickness. Moreover, we find patients with higher anterior corneal curvature has lower HC radius and CCT but higher ARTh than those with lower anterior corneal curvature.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2025]版:
大类 | 4 区 医学
小类 | 3 区 眼科学
最新[2025]版:
大类 | 4 区 医学
小类 | 3 区 眼科学
JCR分区:
出版当年[2023]版:
Q2 OPHTHALMOLOGY
最新[2024]版:
Q3 OPHTHALMOLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版] 出版后一年[2024版]

第一作者:
第一作者机构: [1]Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:28508 今日访问量:0 总访问量:1584 更新日期:2025-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)