机构:[1]Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China[2]Beijing Tongren Hospital, Capital Medical University首都医科大学附属北京同仁医院首都医科大学附属同仁医院[3]Beijing Institute of Ophthalmology, Beijing 100005, China研究所眼科研究所首都医科大学附属北京同仁医院首都医科大学附属同仁医院
AIM: To investigate the relationship between preoperative corneal biomechanical properties and corneal tomographic properties in cataract patients. METHODS: The study consisted of 59 eyes of 30 participants who were diagnosed as cataract in Peking University Third Hospital between September 2019 and November 2019. Stepwise multivariable linear regression analysis was calculated to determine the relationship between corneal biomechanical parameters and tomographic parameters. The patients were classified into three groups of with the rule (WTR) astigmatism, against the rule astigmatism and oblique astigmatism. And the differences in corneal parameters among different groups were compared. RESULTS: There were significant differences in the first applanation time (A1T), the first applanation length (A1L), corneal velocity during the first applanation (Vin), the second applanation time (A2T), highest concavity (HC) radius, displacement amount (DA), DA ratio, stiffness parameter A1 (SPA1) and integrated radius (IR) between oblique astigmatism patients and the other two groups. Total corneal steep meridian (K2) was negatively associated with A1L, A1T and corneal velocity during the second applanation (Vout). Patients with higher anterior corneal curvature had lower HC radius and central corneal thickness (CCT; P=0.001 and 0.006, respectively), while the Ambrosio relational thickness to the horizontal profile (ARTh) was higher than those with lower anterior corneal curvature (P=0.009). CONCLUSION: The study reveals that the elasticity of corneal collagen fibers is greater, but the viscoelasticity of cornea is smaller in patients with oblique astigmatism. There is no significant difference in ARTh between patients with different types of astigmatism, that is, the corneal biomechanical specificity of oblique astigmatism group is probably not caused by corneal thickness. Moreover, we find patients with higher anterior corneal curvature has lower HC radius and CCT but higher ARTh than those with lower anterior corneal curvature.
基金:
China Primary Health Care
Foundation (No.MTP2022C025); Beijing Natural Science
Foundation of China (No.7242168).
第一作者机构:[1]Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
Li Jia-Xi,Liu Yi-He,Liu Yu-Shi,et al.Correlation between corneal biomechanical and tomographic parameters in cataract patients[J].INTERNATIONAL JOURNAL OF OPHTHALMOLOGY.2025,18(7):1282-1293.doi:10.18240/ijo.2025.07.11.
APA:
Li, Jia-Xi,Liu, Yi-He,Liu, Yu-Shi,Liu, Zi-Yuan&Li, Xue-Min.(2025).Correlation between corneal biomechanical and tomographic parameters in cataract patients.INTERNATIONAL JOURNAL OF OPHTHALMOLOGY,18,(7)
MLA:
Li, Jia-Xi,et al."Correlation between corneal biomechanical and tomographic parameters in cataract patients".INTERNATIONAL JOURNAL OF OPHTHALMOLOGY 18..7(2025):1282-1293