Bone reporting and data system on CT (Bone-RADS-CT): a validation study by four readers on 328 cases from three local and two public databases

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Shanghai Jiao Tong Univ, Tongren Hosp, Dept Imaging, Sch Med, Shanghai, Peoples R China [2]Shanghai Jiao Tong Univ, Tongren Hosp, Inst Med Robot, Shanghai Key Lab Flexible Med Robot, Shanghai, Peoples R China [3]Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 6, Dept Orthoped, Sch Med, Shanghai, Peoples R China [4]Tongji Univ, Shanghai Pulm Hosp, Dept Med Oncol, Sch Med, Shanghai, Peoples R China [5]Renhe Hosp, Dept Pathol, Shanghai, Peoples R China [6]Stanford Univ, Dept Epidemiol & Populat Hlth, Sch Med, Stanford, CA USA [7]Boston Univ, Dept Biomed Engn, Boston, MA USA [8]Siemens Healthineers Ltd, MR Res Collaborat Team, Shanghai, Peoples R China [9]Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Radiol, Shanghai, Peoples R China [10]Shanghai Jiao Tong Univ, Tongren Hosp, Dept Nucl Med, Sch Med, Shanghai, Peoples R China
出处:
ISSN:

关键词: Bone neoplasms Clinical decision-making Reproducibility of results Multidetector computed tomography

摘要:
ObjectiveTo evaluate the reproducibility and effectiveness of the bone reporting and data system on CT (Bone-RADS-CT) for incidental solitary bone lesions in adults.Materials and methodsWe retrospectively included 328 CT cases from three local and two public databases, respectively. All the cases were histopathologically or clinically confirmed bone lesions, "do not touch" lesions with typical appearance, and remained stable for at least 2 years. Each lesion with gender, age, and clinical history was categorized according to the Bone-RADS algorithm by two musculoskeletal radiologists and two non-musculoskeletal radiologists. The Bone-RADS categories were as follows: Bone-RADS-1, likely benign, leave alone; Bone-RADS-2, incomplete assessed on imaging, perform different imaging modality; Bone-RADS-3, intermediate, perform follow-up imaging; Bone-RADS-4, suspicious for malignancy or need for treatment, biopsy and/or oncologic referral. Inter-reader agreement was evaluated. The diagnostic performance of the Bone-RADS-CT for distinguishing positive cases (intermediate or malignant lesions or osteomyelitis) from negative cases (benign lesions), were measured, using histopathology results, clinical diagnosis, or follow-up as a standard reference.ResultsThere were 223 positive cases and 105 negative cases, respectively. The overall inter-reader agreement between two musculoskeletal and two non-musculoskeletal radiologists were both moderate (weighted kappa 0.553 and 0.403). The diagnostic performance for identifying intermediate or malignant lesions or osteomyelitis ranged according to radiologists with sensitivities of 88.8% to 94.6%, specificities of 42.9% to 71.1%, and accuracies of 78.0% to 86.6%.ConclusionBone-RADS-CT is effective for identifying bone lesions that need further treatment, but is only moderately reliable for readers of different specialties and experience.Critical relevance statementBone-RADS-CT has been demonstrated to be a reliable algorithm for non-musculoskeletal radiologists and an effective tool for identifying the "need for treatment" incidental solitary bone lesions in adults, but still needs improvement in the rating method and category definition.Key PointsBone-RADS-CT has been demonstrated to be reliable and accurate when rated by musculoskeletal radiologists.Bone-RADS-CT achieved moderate agreement for musculoskeletal and non-musculoskeletal radiologists.Bone-RADS-CT presented high sensitivities but low specificities for identifying "need for treatment" bone lesions.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2024版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版] 出版后一年[2024版]

第一作者:
第一作者机构: [1]Shanghai Jiao Tong Univ, Tongren Hosp, Dept Imaging, Sch Med, Shanghai, Peoples R China [2]Shanghai Jiao Tong Univ, Tongren Hosp, Inst Med Robot, Shanghai Key Lab Flexible Med Robot, Shanghai, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [1]Shanghai Jiao Tong Univ, Tongren Hosp, Dept Imaging, Sch Med, Shanghai, Peoples R China [2]Shanghai Jiao Tong Univ, Tongren Hosp, Inst Med Robot, Shanghai Key Lab Flexible Med Robot, Shanghai, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:28514 今日访问量:5 总访问量:1589 更新日期:2025-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)