高级检索
当前位置: 首页 > 详情页

Relationship Between Retinal Fractal Dimension and Nonperfusion in Diabetic Retinopathy on Ultrawide-Field Fluorescein Angiography

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Doheny Eye Inst, Doheny Image Reading Ctr, 1355 San Pablo St, Los Angeles, CA 90033 USA [2]Univ Calif Los Angeles, David Geffen Sch Med, Dept Ophthalmol, Los Angeles, CA 90095 USA [3]Capital Med Univ, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing, Peoples R China [4]Optos PLC, Dunfermline, Fife, Scotland [5]Retina Consultants Houston, Houston, TX USA [6]Houston Methodist Hosp, Blanton Eye Inst, Houston, TX 77030 USA [7]Weill Cornell Med Coll, Houston, TX USA [8]Univ Texas San Antonio, Med Ctr Ophthalmol Associates, Dept Ophthalmol, San Antonio, TX USA [9]Yeungnam Univ, Coll Med, Dept Ophthalmol, Daegu, South Korea
出处:
ISSN:

摘要:
PURPOSE: To correlate fractal dimension (FD) of the retinal vasculature with the extent of retinal nonperfusion area in diabetic retinopathy (DR) on ultrawide-field fluorescein angiography (FA). DESIGN: Cross-sectional study. METHODS: Baseline Optos 200Tx ultrawide-field FA images of 80 eyes with DR from the DAVE (NCT01552408) and RECOVERY (NCT02863354) studies were stereographically projected at the Doheny Image Reading Center. The retinal vasculature was extracted from an early-phase FA frame by exploiting the elongated nature of the vessels and then skeletonized for calculation of FD using a box -counting method. The nonperfusion area was delineated by 2 independent, reading center certified graders who were masked to the study groups and who were using a standardized protocol and then computed in millimeters squared. RESULTS: While no difference in FD was observed for the entire retina in DR compared with normal control subjects, a significantly smaller FD was found in the far-periphery of the DR eyes (P<.001). FD for the entire retina was negatively associated with global nonperfusion area (R=-0.44; P<.001), and this relationship was also present within the 3 concentric retinal zones (posterior: R=-0.31, P=.016; midperiphery: R=-0.35, P=.007; and far periphery: R=-0.31, P=.015). CONCLUSIONS: Peripheral FD on ultrawide-field FA is reduced in DR eyes compared with normal eyes and is correlated with severity of retinal nonperfusion. FD can be calculated automatically without the need for correction of peripheral distortion, and therefore it may prove to be a useful surrogate biomarker when precise quantification of nonperfusion is not feasible. (C) 2019 Published by Elsevier Inc.)

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
最新[2025]版:
大类 | 1 区 医学
小类 | 1 区 眼科学
JCR分区:
出版当年[2018]版:
Q1 OPHTHALMOLOGY
最新[2024]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者机构: [1]Doheny Eye Inst, Doheny Image Reading Ctr, 1355 San Pablo St, Los Angeles, CA 90033 USA [2]Univ Calif Los Angeles, David Geffen Sch Med, Dept Ophthalmol, Los Angeles, CA 90095 USA [3]Capital Med Univ, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing, Peoples R China
通讯作者:
通讯机构: [1]Doheny Eye Inst, Doheny Image Reading Ctr, 1355 San Pablo St, Los Angeles, CA 90033 USA [2]Univ Calif Los Angeles, David Geffen Sch Med, Dept Ophthalmol, Los Angeles, CA 90095 USA [*1]Univ Calif Los Angeles, Doheny Eye Inst, POB 86228, Los Angeles, CA 90086 USA
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:28494 今日访问量:0 总访问量:1584 更新日期:2025-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)