高级检索
当前位置: 首页 > 详情页

Vitreous Biopsy Under Air: Technique, Complications, and Volume Outcomes

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Beijing Tongren Eye Center, Beijing Key Laboratory of Ophthalmolo­gy and Visual Science, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
出处:
ISSN:

摘要:
BACKGROUND AND OBJECTIVE: Classic vitreous biopsy, which targets the vitreous with an undiluted sample of 1 mL to 2 mL, has been used as a diagnostic analysis. Vitrectomy under air infusions have been reported to be able to extract more vitreous sample. In this study, the authors introduce a way of obtaining vitreous sample under air irrigation using 23-gauge vitrectomy and discuss the benefits and potential risks of this procedure. PATIENTS AND METHODS: In this retrospective case series study, a total of 65 eyes of 65 patients with macular epiretinal membrane (ERM) or macular hole (MH) were enrolled. A vitreous biopsy was carried out with air infusion. Vitrectomy with fluid infusion was then carried out to remove the residual vitreous. Medical records of patients with macular ERM or MH were reviewed and analyzed. Clinical data, including age, sex, best-corrected visual acuity (BCVA), optical coherence tomography (OCT), axial length, presence of posterior vitreous detachment (PVD), presence of liquefication of vitreous, and refraction, were recorded and investigated. The volume of vitreous sample, visual outcome, and complications related to vitreous biopsy at 1-month follow-up were recorded and analyzed. RESULTS: The mean of undiluted vitreous sample volume was 2.1 mL +/- 0.2 mL. There were seven patients whose vitreous samples were less than 2 mL during the vitreous biopsy. The mean age of patients was 62.9 years +/- 8.4 years (range: 35 years to 85 years) at diagnosis. There were 18 male and 47 female patients. At 1-month follow-up, no patient had decreased visual acuity. There was one patient who had a peripheral retinal break and was treated with photocoagulation during the operation (1.5%). The insufficient vitreous sample that may occur during the vitreous biopsy under air infusion was related to liquefication of vitreous (28.8%). CONCLUSION: In summary, vitreous biopsy with air infusion is a safe and effective maneuver to harvest undiluted vitreous in patients without significant vitreous inflammation.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 眼科学 4 区 外科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 眼科学 4 区 外科
JCR分区:
出版当年[2017]版:
Q3 SURGERY Q3 OPHTHALMOLOGY
最新[2024]版:
Q3 OPHTHALMOLOGY Q3 SURGERY

影响因子: 最新[2024版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Beijing Tongren Eye Center, Beijing Key Laboratory of Ophthalmolo­gy and Visual Science, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
通讯作者:
通讯机构: [1]Beijing Tongren Eye Center, Beijing Key Laboratory of Ophthalmolo­gy and Visual Science, Beijing Tongren Hospital, Capital Medical University, Beijing, China. [*1]Beijing Tongren Eye Center, Beijing Key Laboratory of Ophthalmology and Visual Science, Beijing Ton­gren Hospital, Capital Medical University. No. 1 Dongjiaominxiang Street, Dongcheng District, Beijing, China 100730
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:29017 今日访问量:0 总访问量:1619 更新日期:2025-10-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)