高级检索
当前位置: 首页 > 详情页

Spontaneous Eye Blink Patterns in Dry Eye: Clinical Correlations

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Key Laboratory of Ophthalmology and Visual Sciences, Beijing, China [2]Quinze-Vingts National Ophthalmology Hospital, Paris and Versailles Saint-Quentin-en-Yvelines University, Versailles, France [3]INSERM, U968, Paris, F-75012, France.UPMC Univ Paris 06, UMR_S 968, Institut de la Vision, Paris F-75012, France.CNRS, UMR_7210, Paris F-75012, France
出处:
ISSN:

关键词: dry eye partial blink blink patterns inter-blink interval

摘要:
PURPOSE. To evaluate spontaneous eye blink patterns and their correlations with clinical tests in dry eye disease (DED). METHODS. Twenty-five DED patients and 25 healthy subjects were included in this prospective case-controlled study. Clinical evaluations included the Ocular Surface Disease Index (OSDI), lipid layer thickness (LLT), spontaneous eye blink pattern analysis, fluorescein tear film breakup time (FBUT), and so on. Eye blinks were recorded for 20 seconds with a high-speed camera. Eye blink patterns were divided into the following five phases: the eyelid closing phase (ECP), eyelid closed phase (CDP), early opening phase (EOP), late opening phase (LOP), and interblink intervals (IBI). The correlations between blink parameters and clinical tests were analyzed. RESULTS. Compared with the control group, mean ECP, CDP, and EOP were significantly longer in DED patients (P < 0.001, P 0.029, and P < 0.001, respectively). DED patients also had significantly shorter LOP and blink intervals (both P < 0.001) and more partial blinks as compared with control subjects (P = 0.001). FBUT was negatively correlated with ECP (r = -0.618, P = 0.001) and the number of partial blinks (r = -0.413, P = 0.040). There was a positive correlation between OSDI and the number of partial blinks (r = 0.446, P = 0.026). The LLT coefficient of variation (LLT-CV) also showed a positive correlation with ECP, CDP, and LOP (P = 0.001, P = 0.050, P = 0.049, respectively). Corneal and conjunctival staining was positively correlated with ECP, CDP, and the number of blinks (r = 0.449, P = 0.024; r = 0.526, P = 0.007; r = 0.456, P = 0.022, respectively) and negatively correlated with IBI (r = -0.420, P = 0.037). CONCLUSIONS. Partial blinks, prolonged eyelid closed time and short blink intervals were the three main characteristics of DED patients' spontaneous blink patterns.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
JCR分区:
出版当年[2016]版:
Q1 OPHTHALMOLOGY
最新[2024]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者机构: [1]Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Key Laboratory of Ophthalmology and Visual Sciences, Beijing, China
通讯作者:
通讯机构: [1]Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Key Laboratory of Ophthalmology and Visual Sciences, Beijing, China [*1]Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Key Laboratory of Ophthalmology and Visual Sciences, Beijing 100005, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:28514 今日访问量:0 总访问量:1589 更新日期:2025-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)