Consistent comparison of angle Kappa adjustment between Oculyzer and Topolyzer Vario topography guided LASIK for myopia by EX500 excimer laser

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China
出处:
ISSN:

关键词: angle Kappa adjustment Oculyzer Topolyzer uniformity laser in situ keratomileusis

摘要:
AIM: To evaluate and compare the uniformity of angle Kappa adjustment between Oculyzer and Topolyzer Vario topography guided ablation of laser in situ keratomileusis (LASIK) by EX500 excimer laser for myopia. METHODS: Totally 145 cases (290 consecutive eyes) with myopia received LASIK with a target of emmetropia. The ablation for 86 cases (172 eyes) was guided manually based on Oculyzer topography (study group), while the ablation for 59 cases (118 eyes) was guided automatically by Topolyzer Vario topography (control group). Measurement of adjustment values included data respectively in horizontal and vertical direction of cornea. RESULTS: Horizontally, synclastic adjustment between manually actual values (dx(manu)) and Oculyzer topography guided data (dx(ocu)) accounts 35.5% in study group, with mean dx(manu)/dx(ocu) of 0.78 +/- 0.48; while in control group, synclastic adjustment between automatically actual values (dx(auto)) and Oculyzer topography data (dx(ocu)) accounts 54.2%, with mean dx(auto)/dx(ocu) of 0.79 +/- 0.66. Vertically, synclastic adjustment between dy(manu) and dy(ocu) accounts 55.2% in study group, with mean dy(manu)/dy(ocu) of 0.61 +/- 0.42; while in control group, synclastic adjustment between dy(auto) and dy(ocu) accounts 66.1%, with mean dya(uto)/dy(ocu) of 0.66 +/- 0.65. There was no statistically significant difference in ratio of actual values/Oculyzer topography guided data in horizontal and vertical direction between two groups (P=0.951, 0.621). CONCLUSION: There is high consistency in angle Kappa adjustment guided manually by Oculyzer and guided automatically by Topolyzer Vario topography during corneal refractive surgery by WaveLight EX500 excimer laser.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2025]版:
大类 | 4 区 医学
小类 | 3 区 眼科学
JCR分区:
出版当年[2016]版:
Q4 OPHTHALMOLOGY
最新[2024]版:
Q3 OPHTHALMOLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China [*1]Beijing Tongren Eye Center,Beijing Tongren Hospital,Capital Medical University, Beijing Ophthalmology&Visual Sciences Key Lab.Beijing 100730,China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:29059 今日访问量:0 总访问量:1619 更新日期:2025-10-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)