高级检索
当前位置: 首页 > 详情页

Assessment of Myocardial Bridge by Cardiac CT: Intracoronary Transluminal Attenuation Gradient Derived from Diastolic Phase Predicts Systolic Compression

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Inst Diagnost & Intervent Radiol, 600 Yishan Rd, Shanghai 200233, Peoples R China [2]Second Mil Med Univ, Sch Pharm, Dept Pharmaceut Sci, Shanghai 200433, Peoples R China [3]Shanghai Jiao Tong Univ, Sch Med, TongRen Hosp, Dept Sci Res, Shanghai 200050, Peoples R China
出处:
ISSN:

关键词: Coronary computed tomography angiography Myocardial bridge Systolic compression Transluminal attenuation gradient TAG Ischemic heart disease Coronary artery disease

摘要:
Objective: To study the predictive value of transluminal attenuation gradient (TAG) derived from diastolic phase of coronary computed tomography angiography (CCTA) for identifying systolic compression of myocardial bridge (MB). Materials and Methods: Consecutive patients diagnosed with MB based on CCTA findings and without obstructive coronary artery disease were retrospectively enrolled. In total, 143 patients with 144 MBs were included in the study. Patients were classified into three groups: without systolic compression, with systolic compression < 50%, and with systolic compression >= 50%. TAG was defined as the linear regression coefficient between intraluminal attenuation in Hounsfield units (HU) and length from the vessel ostium. Other indices such as the length and depth of the MB were also recorded. Results: TAG was the lowest in MB patients with systolic compression >= 50% (-19.9 +/- 8.7 HU/10 mm). Receiver operating characteristic curve analysis was performed to determine the optimal cutoff values for identifying systolic compression = 50%. The result indicated an optimal cutoff value of TAG as -18.8 HU/10 mm (area under curve = 0.778, p < 0.001), which yielded higher sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy (54.1, 80.5, 72.8, and 75.0%, respectively). In addition, the TAG of MB with diastolic compression was significantly lower than the TAG of MB without diastolic compression (-21.4 +/- 4.8 HU/10 mm vs. -12.7 +/- 8 HU/10 mm, p < 0.001). Conclusion: TAG was a better predictor of MB with systolic compression >= 50%, compared to the length or depth of the MB. The TAG of MB with persistent diastolic compression was significantly lower than the TAG without diastolic compression.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2015]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2024版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Inst Diagnost & Intervent Radiol, 600 Yishan Rd, Shanghai 200233, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [1]Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Inst Diagnost & Intervent Radiol, 600 Yishan Rd, Shanghai 200233, Peoples R China [*1]Institute of Diagnostic and Interventional Radiology, Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, No. 600, Yishan Road, Shanghai 200233, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:28509 今日访问量:5 总访问量:1589 更新日期:2025-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)