高级检索
当前位置: 首页 > 详情页

Macular Bruch's Membrane Length and Axial Length. The Beijing Eye Study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Inst Ophthalmol, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China [2]Heidelberg Univ, Med Fac Mannheim, Dept Ophthalmol, D-69115 Heidelberg, Germany [3]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing, Peoples R China
出处:
ISSN:

摘要:
Purpose To assess whether macular Bruch's membrane gets lengthened in axial myopia. Methods Using the enhanced depth imaging mode of spectral-domain optical coherence tomography and examining a subgroup of participants of the population-based cross-sectional Beijing Eye Study, we measured the length of Bruch's membrane ("MacBMLength") from the fovea to the temporal edge of parapapillary gamma zone, and the distance between the fovea and the temporal optic disc border. Parapapillary gamma zone was defined as the parapapillary region without Bruch's membrane. We additionally measured ocular biometric parameters and assessed non-ophthalmologic variables. Results Measurements of MacBMLength were performed on 322 individuals. MacBMLength (mean: 3.99 +/- 0.33 mm; range: 3.17-4.93 mm) was not significantly associated with any systemic parameter or ocular biometric parameter. Gamma zone width (mean: 0.18 +/- 0.30mm; range: 0.00-2.61mm) was associated (multivariate analysis; correlation coefficient r: 0.80) with longer axial length (P<0.001; standardized correlation coefficient beta: 0.60; non-standardized correlation coefficient B:0.11; 95% CI:0.09,0.14) and with longer fovea-optic disc border distance (P<0.001; beta: 0.28; B: 0.19; 95% CI:0.14,0.25), but not with MacBMLength (P = 0.42). Fovea-temporal disc border distance (mean: 4.16 +/- 0.44mm; range: 3.17-5.86mm) was associated (overall correlation coefficient: 0.68) with longer axial length (P<0.001; beta: 0.36; B: 0.10; 95% CI: 0.06, 0.13), after adjusting for flatter anterior chamber depth (P = 0.003; beta:-0.14; B:-0.14; 95% CI: -0.23,-0.05) and wider parapapillary gamma zone (P<0.001; beta: 0.42; B: 0.62; 95% CI: 0.44,0.81). Conclusions In contrast to parapapillary gamma zone width and fovea-disc border distance, MacBM-Length was not significantly associated with axial length. Axial elongation associated increase in fovea-disc distance may predominantly occur through development or elongation of parapapillary gamma zone, while macular Bruch's membrane may mostly be independent of axial elongation.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 3 区 生物
小类 | 3 区 综合性期刊
最新[2025]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
JCR分区:
出版当年[2013]版:
Q1 MULTIDISCIPLINARY SCIENCES
最新[2024]版:
Q2 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2024版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Inst Ophthalmol, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China [2]Heidelberg Univ, Med Fac Mannheim, Dept Ophthalmol, D-69115 Heidelberg, Germany
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:28967 今日访问量:0 总访问量:1619 更新日期:2025-10-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)