高级检索
当前位置: 首页 > 详情页

Diagnostic accuracy of level IV portable sleep monitors versus polysomnography for pediatric obstructive sleep apnea: a systematic review and meta-analysis

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Otolaryngology, Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China
出处:
ISSN:

关键词: Obstructive sleep apnea Children Level IV portable Monitors Meta-analysis Oximetry-based statistical classifier

摘要:
Background: Obstructive sleep apnea (OSA) is one of the common sleep-related breathing disorders in children. However, polysomnography (PSG) is an expensive and labor-intensive diagnostic modality that may not always be feasible, especially in low-income countries or in non-tertiary hospitals. Portable monitors (PMs), a new approach for OSA diagnosis, have become more widely used with lower intolerance and cost in recent years. We aimed to analyze the diagnostic performance of Level IV PMs compared with PSG for the diagnosis of pediatric OSA. Methods: PubMed and Embase databases were searched for studies published in English up to December 31, 2020 evaluating the diagnostic accuracy of Level IV PMs against the apnea-hypopnea index (AHI) measured using overnight in-laboratory polysomnography (PSG) in children and adolescents. A random effects bivariate model was used to estimate the summary sensitivity and specificity of oximetry-based statistical classifiers. A qualitative evaluation of studies was performed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) rating. Results: In total, 20 studies involving 7062 participants were included in this systematic review. Among these articles, seven studies (oximetry based on new mathematical classifiers) involving 5098 individuals satisfied the criteria for quantitative synthesis. Compared with AHI evaluation measured by PSG, different PM systems achieved diagnostic accuracy with variable degrees of success. A meta-analysis showed a pooled sensitivity of 74% (95% confidence interval [CI]: 66-80%) and pooled specificity of 90% (95% CI: 85-94%). The area under the summary receiver operating characteristic (SROC) curve was 0.89 (95% CI: 0.86-0.92). Conclusion: This study showed the potential of Level IV PMs for screening pediatric OSA patients. Oximetry based on new mathematical classifiers may provide a simple and effective alternative to PSG in the diagnosis of pediatric OSA especially in the context of appropriate clinical evaluation. (c) 2021 Elsevier B.V. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 3 区 医学
小类 | 3 区 临床神经病学
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 临床神经病学
JCR分区:
出版当年[2019]版:
Q2 CLINICAL NEUROLOGY
最新[2023]版:
Q1 CLINICAL NEUROLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Department of Otolaryngology, Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Otolaryngology, Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China [*1]Department of Otolaryngology e Head and Neck Surgery Beijing Tongren Hospital, Capital Medical University, Dongjiaominxiang No.1, Beijing, 100730, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)