高级检索
当前位置: 首页 > 详情页

Optic nerve sheath diameter measured by ultrasonography versus Magnetic Resonance Imaging for diagnosing increased intracranial pressure: a systematic review and meta-analysis

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Ultrasonography, Beijing Tongren Hospital, Capital Medical University, Beijing, China
出处:
ISSN:

关键词: optic nerve sheath ultrasonography intracranial pressure magnetic resonance imaging meta-analysis

摘要:
To compare the accuracy of the optic nerve sheath diameter (ONSD) measured by ocular ultrasonography (US) versus magnetic resonance imaging (MRI) for the diagnosis of increased intracranial pressure (ICP).A systematic search of studies evaluating US ONSD or MRI ONSD for the diagnosis of increased ICP was performed. Data were extracted independently by two authors. We used the bivariate random-effects model to evaluate the diagnostic feasibility of measuring the ONSD in patients increased ICP. A summary receiver operating characteristic (SROC) graph was adopted to calculate sensitivity and specificity. Subgroup analysis was used to explore potential difference in US ONSD and MRI ONSD.A total of 31 studies were included, in which there were 1783 patients diagnosed with US ONSD and 730 patients diagnosed with MRI ONSD. Twenty studies reporting US ONSD were included for quantitative synthesis. The US ONSD had a high diagnostic accuracy, involving estimated sensitivity of 0.92 (95%CI 0.87-0.95), estimated specificity of 0.85 (95%CI 0.79-0.89), positive likelihood ratio (PLR) of 6.0 (95%CI 4.3-8.4), negative likelihood ratio (NLR) of 0.10 (95%CI 0.06-0.15) and Diagnostic Odds Ratio (DOR) of 62 (95%CI 33-117). The data of 11 studies adopting MRI ONSD was pooled. The MRI ONSD demonstrated estimated sensitivity of 0.70 (95%CI 0.60-0.78), estimated specificity of 0.85 (95%CI 0.80-0.90), PLR of 4.8 (95%CI 3.4-6.7), NLR of 0.35 (95%CI 0.27-0.47) and DOR of 13 (95%CI 8-22). The subgroup analysis showed that US ONSD demonstrated a higher sensitivity (0.92 versus 0.70; p<0.01) and almost equal specificity (0.85 vs. 0.85; p=0.67) compared with MRI ONSD.Measurement of ONSD can be a useful tool to predict raised ICP. The US ONSD demonstrated better accuracy than MRI ONSD for the diagnosis of increased ICP.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 声学 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 声学 4 区 核医学
JCR分区:
出版当年[2021]版:
Q3 ACOUSTICS Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 ACOUSTICS Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Department of Ultrasonography, Beijing Tongren Hospital, Capital Medical University, Beijing, China
通讯作者:
通讯机构: [1]Department of Ultrasonography, Beijing Tongren Hospital, Capital Medical University, Beijing, China [*1]Department of Ultrasonography, Beijing Tongren Hospital, Capital Medical University. 1 Dong Jiao Min Xiang Street, Dongcheng District, Beijing 100730, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23624 今日访问量:0 总访问量:1285 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)