高级检索
当前位置: 首页 > 详情页

The Repeatability and Reproducibility of a New Minimally Invasive Method for Orbital Pressure Measurement

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Beijing Tongren Eye Center, Beijing Ophthalmology and Visual Sciences Key Lab, Capital Medical University, Beijing Tongren Hospital, Beijing, China
出处:
ISSN:

关键词: Direct orbital pressure intraocular pressure manometry minimally invasive measurement

摘要:
Evaluation of orbital pressure is crucial for monitoring various orbital disorders. However, there is currently no reliable technique to accurately measure direct orbital pressure (DOP). This study aimed to establish a new method for the DOP as well as to verify its repeatability and reproducibility in rabbits.The study included 30 normal eyes from fifteen 3-month-old New Zealand white rabbits. After administering inhalation anesthesia, intraocular pressure (IOP) was determined by tonometry (Tonopen). For DOP manometry, a TSD104 pressure transducer was inserted between the disposable injection needle and the syringe, and the output results were displayed on a computer. Two observers independently participated in the experiment to verify its repeatability and reproducibility.The mean IOP of rabbits was significantly higher than the DOP in normal rabbits (11.67 ± 1.08 mm Hg versus 4.91 ± 0.86 mm Hg, P < 0.001). No significant interocular difference was detected for both IOP and DOP (P > 0.05). A high correlation was found for intraobserver measurements of both IOP (intraclass correlation coefficient = 0.87, P < 0.001) and DOP (intraclass correlation coefficient = 0.89, P < 0.001). A high agreement was also presented for the interobserver reproducibility for the measurements of IOP [Pearson correlation coefficient (R) = 0.86, P < 0.001] and DOP (R = 0.87, P < 0.001). Direct orbital pressure was positively correlated with IOP in both observers (R1 = 0.66, R2 = 0.62, P < 0.001). The Bland-Altman plots revealed that 5.0% (3/60) of the IOP and DOP measurement points were outside of the 95% limits of agreement, respectively.The TSD104 pressure transducer-based manometry may serve as a reliable device for the measurement of DOP, providing real-time measuring results with acceptable reproducibility and repeatability.Copyright © 2023 by Mutaz B. Habal, MD.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 外科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 外科
JCR分区:
出版当年[2021]版:
Q4 SURGERY
最新[2023]版:
Q3 SURGERY

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Beijing Tongren Eye Center, Beijing Ophthalmology and Visual Sciences Key Lab, Capital Medical University, Beijing Tongren Hospital, Beijing, China
通讯作者:
通讯机构: [1]Beijing Tongren Eye Center, Beijing Ophthalmology and Visual Sciences Key Lab, Capital Medical University, Beijing Tongren Hospital, Beijing, China [*1]Beijing Tongren Eye Center/ Capital Medical University/Beijing Tongren Hospital, 1# Dong Jiao Min Lane, Beijing 100730, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23459 今日访问量:6 总访问量:1282 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)