高级检索
当前位置: 首页 > 详情页

Performance of Updated Stress-Strain Index in Differentiating between Normal, Forme-Fruste, Subclinical and Clinical Keratoconic Eyes

文献详情

资源类型:
Pubmed体系:
机构: [1]National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University, Wenzhou 325027, China [2]Shanghai Eighth People's Hospital, Shanghai 200235, China [3]School of Engineering, University of Liverpool, Liverpool L69 3GH, UK [4]The Institute of Ocular Biomechanics, Wenzhou Medical University, Wenzhou 325027, China [5]National Institute for Health Research (NIHR) Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK [6]Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100083, China
出处:
ISSN:

关键词: forme fruste keratoconus subclinical keratoconus corneal biomechanics updated stress-strain Index Corvis ST

摘要:
This study seeks to evaluate the ability of the updated stress strain index (SSIv2) and other Corvis ST biomechanical parameters in distinguishing between keratoconus with different disease stages, and normal eyes.Diagnostic accuracy analysis to distinguish disease stages.1084 eyes were included and divided into groups of normal (199 eyes), forme fruste keratoconus (FFKC, 194 eyes), subclinical keratoconus (SKC, 113 eyes), mild clinical keratoconus (CKC-I, 175 eyes), moderate clinical keratoconus (CKC-II, 204 eyes) and severe clinical keratoconus (CKC-III, 199 eyes). Each eye was subjected to a Corvis ST examination to determine the central corneal thickness (CCT), biomechanically corrected intraocular pressure (bIOP), SSIv2 and other eight Corvis parameters including the SSIv1, SP-A1, A1T, ARTh, IIR, DAM, DARatio2 and CBI. The sensitivity and specificity of these parameters in diagnosing keratoconus were analyzed through receiver operating characteristic curves.Before and after correction for CCT and bIOP, SSIv2 and ARTh were significantly higher, and IIR and CBI were significantly lower in the normal group than in the FFKC group, SKC group and the 3 CKC groups (all P<0.05). There were also significant correlations between the values of SSIv2, ARTh, IIR, CBI and the CKC severity (all P<0.05). AUC of SSIv2 was significantly higher than all other Corvis parameters in distinguishing normal eyes from FFKC, followed by IIR, ARTh and CBI.Corvis ST's updated SSI demonstrated superior performance in differentiating between normal and keratoconic corneas, and between corneas with different keratoconus stages. Similar, but less pronounced, performance was demonstrated by the IIR, ARTh and CBI.Copyright © 2023. Published by Elsevier Inc.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 1 区 医学
小类 | 1 区 眼科学
最新[2023]版:
大类 | 1 区 医学
小类 | 1 区 眼科学
第一作者:
第一作者机构: [1]National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University, Wenzhou 325027, China
通讯作者:
通讯机构: [1]National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University, Wenzhou 325027, China [4]The Institute of Ocular Biomechanics, Wenzhou Medical University, Wenzhou 325027, China [*1]No. 270 Xueyuan West Road, WenZhou City, ZheJiang Prov, 325027, China [*2]No. 270 Xueyuan West Road, WenZhou City, ZheJiang Prov, 325027, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)