Lamina Cribrosa Configurations in Highly Myopic and Non-Highly Myopic Eyes: The Beijing Eye Study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China. [2]Singapore Eye Research Institute, Singapore National Eye Centre, Singapore. [3]Rothschild Foundation Hospital, Institut Français de Myopie, Paris, France. [4]Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China.
出处:
ISSN:

关键词: high myopia (HM) optic nerve head (ONH) lamina cribrosa depth (LCD) lamina cribrosa tilt (LCT) optical coherence tomography (OCT)

摘要:
The purpose of this study was to examine characteristics of lamina cribrosa (LC) configuration in highly myopic (HM) eyes.Participants from the Beijing Eye Study 2011, free of optic nerve or retinal diseases, were randomly selected to examine LC depth (LCD) and LC tilt (LCT) using three-dimensional optical coherent tomography images of the optic nerve head (ONH). LCD and LCT were measured as the distance and angle between the LC plane with two reference planes, including the Bruch's membrane opening (BMO) plane and the peripapillary sclera (PPS) plane, respectively. Each parameter was measured in both horizontal and vertical B-scans.The study included 685 individuals (685 eyes) aged 59.6 ± 7.7 years, including 72 HM eyes and 613 non-HM eyes. LCD measurements showed no significant differences between HM eyes and non-HM eyes in both horizontal (LCD-BMO = 421.83 ± 107.86 µm for HM eyes vs. 447.24 ± 104.94 µm for non-HM eyes, P = 0.18; and LCD-PPS = 406.39 ± 127.69 µm vs. 394.00 ± 101.64 µm, P = 1.00) and vertical directions (LCD-BMO = 435.78 ± 101.29 µm vs. 450.97 ± 106.54 µm, P = 0.70; and LCD-PPS = 401.62 ± 109.9 µm vs. 379.85 ± 110.35 µm, P = 0.35). However, the LCT was significantly more negative (tilted) in HM eyes than in non-HM eyes horizontally (LCT-BMO = -4.38 ± 5.94 degrees vs. -0.04 ± 5.86 degrees, P < 0.001; and LCT-PPS = -3.16 ± 5.23 degrees vs. -0.94 ± 4.71 degrees, P = 0.003), but not vertically (P = 1.00).Although LCD did not differ significantly between HM and non-HM eyes, LCT was more negative in HM eyes, suggesting that the temporal or inferior side of the LC was closer to the reference plane. These findings provide insights into morphological and structural changes in the LC and ONH between HM and non-HM eyes.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
JCR分区:
出版当年[2022]版:
Q1 OPHTHALMOLOGY
最新[2023]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23594 今日访问量:3 总访问量:1285 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)