高级检索
当前位置: 首页 > 详情页

Comparison of femoral tunnel position and knee function in anterior cruciate ligament reconstruction: a retrospective cohort study using measuring-fluoroscopy method versus bony marker method

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Orthopedics, Beijing Tongren Hospital, Capital Medical University, Beijing, China [2]Department of Anesthesiology, Beijing Tongren Hospital,Capital Medical University, Beijing, China.
出处:

关键词: ACL rupture Anatomical reconstruction Bony landmarks Measuring method Apex Cartilage Fluoroscopy Function

摘要:
Previous studies have shown that surgical technique errors especially the wrong bone tunnel position are the primary reason for the failure of anterior cruciate ligament (ACL) reconstruction. In this study, we aimed to compare the femoral tunnel position and impact on knee function during the ACL reconstruction using measuring combined with fluoroscopy method and bony marker method for femoral tunnel localization.A retrospective cohort study of patients undergoing ACL reconstruction using the bony marker method or measuring combined with fluoroscopy for femoral tunnel localization was conducted between January 2015 and January 2020. A second arthroscopic exploration was performed more than 1 year after surgery. Data regarding patient demographics, the femoral tunnel position, results of the Lysholm score, the International Knee Documentation Committee (IKDC) score, KT-1000 side-to-side difference, pivot shift grade, and Lachman grade of the knee were collected.A total of 119 patients were included in the final cohort. Of these, 42 cases were in the traditional method group, and 77 cases were in the measuring method group. The good tunnel position rate was 26.2% in the traditional method group and 81.8% in the measuring method group (p < 0.001). At the final follow-up, the Lysholm and IKDC scores were significantly greater in the measuring method group than the traditional method group (IKDC: 84.9 ± 8.4 vs. 79.6 ± 6.4, p = 0.0005; Lysholm: 88.8 ± 6.4 vs. 81.6 ± 6.4, p < 0.001). Lachman and pivot shift grades were significantly greater in the measuring method group (p = 0.01, p = 0008). The results of KT-1000 side-to-side differences were significantly better in the measuring method group compared with those in the traditional method group (p < 0.001).The combination of the measuring method and intraoperative fluoroscopy resulted in a concentrated tunnel position on the femoral side, a high rate of functional success, improved knee stability, and a low risk of tunnel deviation. This approach is particularly suitable for surgeons new to ACL reconstructive surgery.© 2024. The Author(s).

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 3 区 骨科 3 区 风湿病学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 骨科 3 区 风湿病学
JCR分区:
出版当年[2022]版:
Q2 ORTHOPEDICS Q4 RHEUMATOLOGY
最新[2023]版:
Q2 ORTHOPEDICS Q3 RHEUMATOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Department of Orthopedics, Beijing Tongren Hospital, Capital Medical University, Beijing, China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)