高级检索
当前位置: 首页 > 详情页

A Survey of Mean Glandular Doses and Suggestions on National Diagnostic Reference Levels for Digital Mammography in China

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Key Laboratory of Radiological Protection and Nuclear Emergency Chinese Center for Disease Control and Prevention, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing, China. [2]Beijing Center for Diseases Prevention and Control, Beijing, China. [3]Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
出处:
ISSN:

关键词: dose organ mammography patient protection radiation protection

摘要:
The primary purpose of this study was to report the mean glandular doses and to determine the national diagnostic reference levels for digital mammography based on data between 2016 and 2018 in China. The data from 19,076 mammograms (4,769 examinations) by random sampling from 118 digital mammography systems were compiled. Exposure factors included age, compressed breast thickness, kVp, mAs, target/filter combination, entrance surface air kerma, and mean glandular doses, which were retrospectively surveyed and recorded from the monitor. The national diagnostic reference levels (75th percentiles) in mean glandular dose were calculated across median value obtained for all included data and stratified to specific compressed breast thickness ranges. The patients' ages ranged from 22 to 88 y, with a median age of 45. The applied voltage and output medians were 28 kVp and 75.1 mAs for all exposure, respectively. The median CBTs were 45 mm and 48 mm for craniocaudal views and mediolateral oblique views, and the corresponding median mean glandular doses were 1.32 mGy and 1.40 mGy, respectively. The national diagnostic reference level at compressed breast thickness of 40-50 mm was 1.67 mGy for CC views and 1.71 mGy for MLO views. The median mean glandular doses varied significantly and increased with compressed breast thickness, demonstrating the necessity of establishing DRL according to breast thickness and optimizing the clinic's digital mammography practice in China.Copyright © 2024 Health Physics Society.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 4 区 医学
小类 | 4 区 环境科学 4 区 核科学技术 4 区 公共卫生、环境卫生与职业卫生 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 环境科学 4 区 核科学技术 4 区 公共卫生、环境卫生与职业卫生 4 区 核医学
JCR分区:
出版当年[2022]版:
Q2 NUCLEAR SCIENCE & TECHNOLOGY Q3 ENVIRONMENTAL SCIENCES Q3 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q3 NUCLEAR SCIENCE & TECHNOLOGY Q4 ENVIRONMENTAL SCIENCES Q4 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Key Laboratory of Radiological Protection and Nuclear Emergency Chinese Center for Disease Control and Prevention, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing, China.
通讯作者:
通讯机构: [1]Key Laboratory of Radiological Protection and Nuclear Emergency Chinese Center for Disease Control and Prevention, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing, China. [*1]Key Laboratory of Radiological Protection and Nuclear Emergency Chinese Center for Disease Control and Prevention, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23621 今日访问量:3 总访问量:1285 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)